Canon GM-1000 ユーザーズマニュアル

ページ / 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
22
2.8.2.  RS-232C command input 
RS-232C command input allows the following: 
• Operation 
setting 
• Parameter 
setting 
• Error 
processing 
• Status 
check 
  (For details, see 8.  “Commands”) 
    In case not using high-speed serial communication, RS-232C communication command input is enough 
for the following function: 
• Step 
movement 
• Raster 
scan 
(Continuous 
oscillation of a certain angle at a fixed frequency) 
 
 (Communication specifications) 
Wiring Cross 
wiring 
Communication rate 
38400 bps 
Data length 
8 bits 
Stop bit 
Parity None 
Data format 
ASCII code 
Delimiter code 
LF (0x0a) or CR (0x0d)