Canon GM-1000 ユーザーズマニュアル

ページ / 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
30
Parameter ID 
Data 
13 
(High-speed serial communication 
conversion gain parameter) 
 
Magnification ×1000 
E.g.    For x2 (parameter ID = 13 setting: 2000), the following angle can be specified: 
       
  
-1.44 × 2 deg ~ 1.44 × 2 deg (GM-1010) 
         
 
-0.96 × 2 deg ~ 0.96 × 2 deg (GM-1015, 1020) 
   
 
The command resolution will be two times