Notes: 
•  In the “Reading” column, “„” means “Enable reading” and “X” means “Disable 
reading.” 
•  In the “Transmit code length” column, “„” means “Transmit code length” and 
X” means “Do not transmit code length.”  
•  In the “Transmit CD” column, “„” means “Transmit check digit” and “X” means 
“Do not transmit check digit.” 
•  In the “Calculate CD” column, “„” means “Calculate check digit” and “X” 
means “Do not calculate check digit”. 
10.3. Default Settings 2: Read Options, Trigger, Buzzer 
Item Default 
Setting 
Setting the number of characters 
Fixed length OFF all codes 
Read mode 
Multiple read 
Multiple read reset time 
500 ms 
Add-on wait mode 
500 ms 
Multiple read 
Disable multiple read 
Multiple columns read 
Disable multiple columns read 
Redundancy  
Read 1 times, redundancy = 0 
Trigger switch 
Enable trigger 
Trigger repeat 
Disable trigger repeat 
Auto trigger 
Disable auto trigger 
Read time  
2 seconds 
Margin check 
Margin check normal 
Buzzer duration 
50 ms 
Buzzer tone 
3 kHz (single tone) 
Buzzer loudness 
Maximum 
Buzzer timing 
Buzzer before transmission 
Startup buzzer 
Enable startup buzzer 
Indicator duration 
200 ms