15. Auto Trigger (Option) 
The OPR 3001 has an optional auto trigger setting, which starts barcode reading automatically 
by using sensor detection. When auto trigger is enabled, a laser beam is emitted and points to 
the auto trigger area. The scanner starts barcode reading after detecting reflection from the 
surface when the auto trigger is used. 
Auto trigger distance: 40 mm from the edge of the scanner. 
Conditions 
Moving Speed: 
100 ±10 mm/s 
Angle: 
Skew angle, excluding pitch angle and dead zone 
Environmental Temperature and 
Humidity: 
Room temperature and humidity 
Environmental luminance: 
500 to 900 lx 
Conditions for the auto trigger: 
1. Barcode sheet: OPTOELECTRONICS Test Sheet (white) 
   Background: OPTOELECTRONICS Test Sheet (black) 
2. Barcode sheet: OPTOELECTRONICS Test Sheet (black) 
   Background: OPTOELECTRONICS Test Sheet (white) 
 
 
Figure 27: Auto trigger