6. Optical 
Specifications 
6.1.  Laser Scanning Specification 
Parameter Specification  Unit 
Light-emitting Element 
Red laser diode 
Emission Wavelength 
650 ±10 (25° C) 
nm 
Light Output 
1.0 or less 
mW 
Scanning Method 
Bi-directional scanning  
Scanning Speed 
100 ±20 
scans/s 
Scan angle: 54 ±5 
° 
Scan Angle 
Effective scan angle: 44 (Min) 
° 
6.2.  Laser Scanning Standard 
6.2.1. 
Laser Scanning Tilt 
Laser scanning tilt is the vertical difference between both ends of a laser scan 
line. Measure it in the middle of the laser scan line. 
•  Up to 1.2 degrees angle in vertical direction from the scan origin (mirror 
motor). 
•  Up to 3.1 mm at 150 mm from the scan origin. 
6.2.2. 
Scanning Curvature 
The maximum difference between the laser scan line and the line between both 
ends of the laser scan line. Measure it in the middle of the laser scan line. 
•  Up to 1.27 degrees angle in vertical direction from the scan origin (mirror 
motor). 
•  Up to 3.3 mm at 150 mm from the scan origin. 
 
Figure 2: Laser scanning tilt and curvature