Opticon LPN5627 ユーザーズマニュアル

ページ / 67
Manual No. 25-ULPNR101-03; Feb, 2003                          LPN5627 / LPR5627 Laser Fixed Mount
Scanner
Page  22
T3
Volume = Minimum
V5
Ring buzzer once at 3kHz for 200 mS
V6
Ring buzzer at 3kHz & 2kHz  for 200 mS
V7
Ring buzzer  at 2kHz & 3kHz for 200 mS
W0
Disable Buzzer
W1
Enable buzzer at 3kHz
W2
Enable buzzer at 3kHz with 2.5kHz interval
W3
Enable buzzer at 2kHz with 3kHz interval
W4
Buzzer duration 0.10 sec
W5
Buzzer duration 0.20 sec
W6
Buzzer duration 0.40 sec
W7
Buzzer duration 0.05 sec
W8
Buzzer duration 0.01 sec
Positive & Negative Bar Codes
V4
Positive bar codes only
V2
Both positive and negative bar codes
Setting the Trigger Function
S7
Disable the trigger function (Laser On)
S8
Enable the trigger function (Laser OFF until
the trigger is activated )
Z
Activate the trigger; turns the laser ON
Selecting the Read Mode
S0
Single Read Mode  (Trigger must be Enabled,
S8)
S1
Multiple Read Mode
S2
Continuous Read Mode
7H
Does not allow first bar distortion
7I
Allow first bar distortion
7O
Normal scan
Scanner Timeout (Trigger Enabled Mode)
Y0
Laser remains ON as long as trigger is pulled
(hardware trigger only)
Y1
1 second after triggering
Y2
2 second after triggering
Y3
3 second after triggering
Y4
4 second after triggering
Y5
6 second after triggering
Y6
8 second after triggering
Y7
10 second after triggering
Redundant Decoding
X0
Read bar code once
X1
Read bar code twice before transmitting
X2
Read bar code three times before transmitting
X3
Read bar code four times before transmitting
7R
Read bar code five times before transmitting
7S
Read bar code six times before transmitting
Xmit Error  (Trigger Enabled Mode only)
5E
Do not Xmit error code
5F
Xmit “BR” <CR> for bad read or no read
5G
Xmit <STX> ”>” <ETX> for bad read;  <STX>
“?” <ETX> for no read
5H
Xmit “>” <CR> for bad read,”?” <CR> or no
read
5I
Transmit “<CAN>” <CR> for bad read or no
read
5J
Xmit  “<CAN>”<ETX> for bad read or no read
Print Quality Adjustment
X4
For lower density, poor print (low gain)
X5
For high density, good print quality bar code
without voids (high gain)
X6
Xmit data  from Low or High gain