Opticon OPR 2001 ユーザーズマニュアル

ページ / 42
Opticon 
OPR 2001 
Specifications Manual 
 
 
 
 
33 
10.3. Default Settings 2: Read Options, Trigger, Buzzer 
Item Default 
Setting 
Setting the number of characters 
Fixed length OFF all codes 
Read mode 
Single read 
Multiple read reset time 
500 ms 
Add-on wait time  
500 ms 
Multiple columns read 
Disabled 
Default option 
([X0] setting) 
Read 1 times, redundancy = 0 
 
 
 
 
 
Redundancy  
Other options 
([X1 .. X3] setting) 
([BS .. BW] setting) 
Read n times, redundancy = n+1 
for following symbologies and lengths: 
  ●  Code39 with length <= 5 
  ●  MSI/Plessey with length <= 4 
  ●  IATA,Industrial 2of5, Interleaved 2of5  
      with length <= 8  
  ●  Matrix 2of5 (& Chin.Post), Scode  
      with length <= 8  
  ●  Codabar (NW7) with all lengths 
  ●  Code-11 with length <= 5 
Trigger switch 
Enabled 
Trigger repeat 
Disable trigger repeat 
Auto trigger 
Disable auto trigger 
Margin check 
Margin check normal 
Buzzer duration 
50 ms 
Buzzer tone 
3 kHz (single tone) 
Buzzer loudness 
Loud (Maximum) 
Buzzer timing 
Buzzer before transmission 
Startup buzzer 
Enable startup buzzer 
Indicator duration 
200 ms