Programming/Editing Optional Settings
Motorola systems use talk group ID's in multiples of 16. 
ID numbers that fall between these ID's indicate special 
status flags for the system. This setting determines how 
the scanner will handle ID's that are not multiples of 16. 
Select your setting then press E.
Ignore
 - the scanner rounds all received ID's down to the 
next interval of 16.
Yes
 - the scanner treats all received ID's as unique ID's.
Note: The default setting is Ignore.
Setting the End Code Operation
(Motorola Systems Only)
 
 program system 
 
E
   
Select the system 
 
E
 
Edit Sys Option 
 
E
 
Set End Code
 
E
This setting determines how the scanner handles the 
transmission end code sent by most Motorola systems. 
Select your setting then press E.
Yes
 - the scanner immediately returns to the control 
channel when it detects the end code.
Ignore
 - the scanner does not return to the control channel 
until the carrier drops.
Note: The default setting is Yes.
Setting I-Call 
(Motorola and EDACS Systems Only)
 
 program system 
 
E
   
Select the system 
 
E
 
Edit Sys Option 
 
E
 
Set I CALL
 
E
This setting determines how your scanner treats I-calls 
while ID Searching.