Install the Kit
3A1324B
5
Install the Power CAN Cables
Systems with a USB Module
1.
See F
IG
. 3. Connect cable (413) to J6 of the display 
module and to connector P3 of the USB module.
2.
Connect saved cable (412) to connector P4 of the 
USB module and to J8 of the Advanced Fluid Con-
trol Module.
3.
Connect the power supply CAN cable (C, F
. 2) to 
J7 on the Advanced Fluid Control Module (F
IG
. 3).
4.
See your ProMix 2KE Operation manual for instruc-
tions on using the USB module.
Systems without a USB Module
1.
See F
. 4. Connect cable (413) to J6 of the display 
module and to J8 of the Advanced Fluid Control 
Module.
2.
Connect the power supply CAN cable (C, F
. 2) to 
J7 on the Advanced Fluid Control Module (F
F
IG
. 3. Install Power CAN Cables (with USB Module)
TI16602a
USB Module (if present)
Advanced Fluid Control Module
TI16604a
J7
Connect 
cable (C) 
here
P3
Connect cable 
(413) here
J6
Connect cable (413) here
P4
Connect cable
(412) here
TI16579a
TI16580a
Display Module
J8
Connect
cable
(412) here
F
IG
. 4. Install Power CAN Cables (without USB 
Module)
TI16602a
Advanced Fluid Control Module
TI16604a
J7
Connect 
cable (C) 
here
J6
Connect cable (413) here
TI16579a
Display Module
J8
Connect
cable
(413) here