DWBS Testing
4-2
Issue 5   June 1999 
1. Contact the Initialization and Administration System (INADS) center for the 
appropriate firmware download.
2. Perform a firmware upgrade for the appropriate component(s) by following 
the directions in the next section (for the WT) or in the DWBS Maintenance 
document (for the other DWBS components).
Procedure: WT Firmware Download 
and Connection
The firmware for the 9601 or 9630 Series WT is updated via the download cable 
connected to the TN789 RC circuit pack that is administered as a download 
server. For the 9601 WT, a 9600 baud RS232 connection is used; for the 9630 
Series WT, a 38400 baud RS232 connection is used. The download cable must 
be within 50 feet of the RC circuit pack. For longer distances, range-extension 
devices are required.
Determining if a Firmware Download is 
Required
The following procedure is required for all new, existing, or replacement WTs.
1. From the DEFINITY ECS management terminal (MT), enter the status 
wt-upgrade command (for firmware that is stored in the RC). This 
command brings up the Status of Wireless Terminal Firmware Upgrade 
form. An example of the form appears as follows: