Lucent Technologies 555-232-102 ユーザーズマニュアル
DWBS Testing
4-2
Issue 5 June 1999
1. Contact the Initialization and Administration System (INADS) center for the
appropriate firmware download.
2. Perform a firmware upgrade for the appropriate component(s) by following
the directions in the next section (for the WT) or in the DWBS Maintenance
document (for the other DWBS components).
document (for the other DWBS components).
Procedure: WT Firmware Download
and Connection
and Connection
The firmware for the 9601 or 9630 Series WT is updated via the download cable
connected to the TN789 RC circuit pack that is administered as a download
server. For the 9601 WT, a 9600 baud RS232 connection is used; for the 9630
Series WT, a 38400 baud RS232 connection is used. The download cable must
be within 50 feet of the RC circuit pack. For longer distances, range-extension
devices are required.
connected to the TN789 RC circuit pack that is administered as a download
server. For the 9601 WT, a 9600 baud RS232 connection is used; for the 9630
Series WT, a 38400 baud RS232 connection is used. The download cable must
be within 50 feet of the RC circuit pack. For longer distances, range-extension
devices are required.
Determining if a Firmware Download is
Required
Required
The following procedure is required for all new, existing, or replacement WTs.
1. From the DEFINITY ECS management terminal (MT), enter the status
wt-upgrade command (for firmware that is stored in the RC). This
command brings up the Status of Wireless Terminal Firmware Upgrade
form. An example of the form appears as follows:
command brings up the Status of Wireless Terminal Firmware Upgrade
form. An example of the form appears as follows: