Dacor DHI482 ユーザーズマニュアル

ページ / 16
7
i
nsTallaTion
 i
nsTruCTions
 WARNING
Do not install the range hood unless the electrical
service provided meets the range hood specifications.
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
A qualified technician must complete the installation
of this built-in appliance. The owner is responsible to
make sure the hood is properly installed.
To avoid an electric shock hazard and property
damage, locate electric wires and water pipes and
avoid drilling in the vicinity.
The range hood is heavy. To prevent personal
injury and property damage install the hood only as
specified below. Make sure all screws used to mount
and assemble the hood are tight.
e
lectric
 S
erVice
 i
nStallation
The electrical connection box must be:
Connected to a 120 Vac, 60 Hz dedicated, grounded,
circuit protected by a 15 Amp circuit breaker or time
delay fuse.
Located a minimum of 17” (43.2 cm) above the bottom
of the range hood.
m
ountinG
 B
racket
 i
nStallation
Locate the mounting bracket and position it against the
1.
ceiling at the previously determined mounting location
(see page 5).
Using a pencil, mark the four mounting hole locations
2.
on the ceiling.
Drill four 1/16” (1.6 mm) pilot holes at the mounting
3.
hole locations.
Attach the bracket using four #12 screws (not
4.
supplied). Make sure the screws penetrate into the
wood mounting surfaces 1 1/2” (3.8 cm).
a
SSemBle
 
the
 h
ooD
 WARNING
Lifting and hanging the range hood requires two
people. Do not attempt to lift the hood without
assistance.
Place the hood assembly on a soft surface with the
1.
bottom side down during assembly to avoid damage.
Tip the hood up on it’s side and remove the filter(s) to
2.
reduce weight and avoid damage.
Inside the exhaust outlet(s) there are metal or plastic
3.
damper flaps. The flaps close to help prevent back-
drafts when the blower is turned off. Make sure all the
flaps open and close freely before proceeding. Remove
any shipping tape that may be present.
Remove the tape that holds the wiring in place on top
4.
of the hood during shipment.
On models with two blowers: Put the exhaust cowling
5.
over the blower outlets on the top of the hood. Fasten
the cowling in place with 14 machine screws.