Sanyo CVW-EXA124 ユーザーズマニュアル

ページ / 30
 
 
26
7.2  Replacing Electronic Ballasts 
 
 
 
 
 
 
 
 
 
 
 
 
 
CVW-EXA124/224 CVW-EXA184/284 
Type Model  Part 
Number 
Quantity used 
Quantity used 
3-lamp QHE3X32T8/UNV 
ISN-SC-1-CC-B  8FC05400000301 
2-lamp QHE2X32T8/UNV 
ISN-SC-1-CC-B  8FC05400000201 
 
 
WARNING! 
Make sure that all Electronic Ballasts Harness plugs are placed firmly in their sockets to prevent damage to the ballast 
and/or the case. 
 
Electronic Ballast Part Codes 
To replace electronic ballasts: 
① 
Remove the Exterior Top Panel. 
② 
Unplug the Electronic Ballast Harness(es). 
③ 
Remove the Electronic Ballast(s). 
Exterior Top 
Panel 
Ballast