Additional Battery Temperature Sensors (Part #: 808-0232-01) can be installed on 
your XC Series or BC Series battery charger. Xantrex recommends that you install 
Battery Temperature Sensors on all banks to protect your batteries and to provide 
optimal charging of each bank. See the label on the outside of the package for 
other Xantrex products compatible with this battery temperature sensor.
Installing Battery Temperature Sensor
To install a BTS:
1.
Switch off all devices operating from the battery.
2.
Connect the ring terminal on the sensor directly to the negative battery stud, 
or use the adhesive backing on the sensor back to attach the sensor to any side 
of the battery to be monitored.
Xantrex recommends you mount the sensor directly on the battery stud as it 
will be more reliable against vibration and will provide a good thermal 
connection to the battery as well.
3.
Route the sensor cable to the charger and plug it into the Bank 1 (default if 
using only one BTS), Bank 2 or Bank 3 connector on the rear panel.
It may be advantageous to temporarily apply a layer of tape around the 
connector to protect its locking tab from catching on something during pulling 
and routing.