HP (Hewlett-Packard) 354903-001 ユーザーズマニュアル
12
HP MSA 500 G2 Storage System Maintenance and Service Guide
−
In RAID 1+0 configurations, any drives that are not mirrored to other
removed or failed drives can be simultaneously replaced offline without
data loss.
removed or failed drives can be simultaneously replaced offline without
data loss.
To remove the component:
CAUTION: To prevent improper cooling and thermal damage,
do not operate the storage system unless all bays are populated with
either a component or a blank.
either a component or a blank.
1. Determine the status of the hard drive from the hot-plug hard drive LEDs
("Hot-Plug SCSI Hard Drive LEDs" on page
2. Back up all data on the hard drive.
3. Remove the hard drive.
To replace the hot-plug SCSI hard drive:
1. Slide the drive into the cage until it clicks, locking the drive into place.
2. Close the lever.
3. Be sure that the drive LEDs illuminate one at a time and then turn off
together to indicate that the system has recognized the new drive.
In fault-tolerant configurations, allow the replacement drive to be
reconstructed automatically with data from the other drives. While
reconstruction is in progress, the online LED flashes.
reconstructed automatically with data from the other drives. While
reconstruction is in progress, the online LED flashes.