Quadra-fire  •  QV32B-A, QV36B-A  •  2014-900  Rev. F  •  9/06
Figure 5.
Framing Dimensions
Framing should be
constructed of 2 X 4
lumber or heavier.
WARNING:
To ensure proper clearances the front
framing header must be installed on its
narrow edge and to the front of the frame.
The framing headers may rest
on the fireplace stand-offs.
VENT
FRAMING
HOLE
E
D
Model
A
B
C
D
E *
QV36B-A
42”
38-1/4” 16-1/4”
41”
27-7/8”
QV32B-A
37”
33”
16-1/4”
36-1/2”
24-3/8”
A
B
C
Step 2.  Framing the Fireplace
Fireplace framing can be built before or after the fireplace
is set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.
*The center of the framing hole is one (1)
inch (25.4mm) above the center of the
horizontal vent pipe.
WALL STUD
NON-COMBUSTIBLE ZONE
IS DEFINED BY 3” ABOVE THE
ELBOW FOR THE ENTIRE
 WIDTH AND DEPTH (BEHIND THE
FRONT HEADER) OF THE FIREBOX.
3 1/2”
3