EXTENSION CORdS
Use  proper  extension  cords.  Make  sure  your  extension  cord  is  in  good  condition  and  is  a  3-
wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the 
machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the
machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig.
D-1 or D-2, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier
gauge. The smaller the gauge number, the heavier the cord.
Fig. d-1
Fig. d-2
MINIMUM gAUgE EXTENSION CORd 
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
  Ampere 
 
Total Length 
gauge of 
 
Rating 
Volts 
of Cord in Feet 
Extension Cord
 
0-6 
120 
up to 25 
18 AWg 
  0-6 
120 
25-50 
16 AWg 
  0-6 
120 
50-100 
16 AWg 
  0-6 
120 
100-150 
14 AWg
  6-10 
120 
up to 25 
18 AWg 
  6-10 
120 
25-50 
16 AWg 
  6-10 
120 
50-100 
14 AWg 
  6-10 
120 
100-150 
12 AWg      
  10-12 
120 
up to 25 
16 AWg 
  10-12 
120 
25-50 
16 AWg 
  10-12 
120 
50-100 
14 AWg 
  10-12 
120 
100-150 
12 AWg
  12-16 
120 
up to 25 
14 AWg 
  12-16 
120 
25-50 
12 AWg 
  12-16 
120 
GREATER THAN 50 FEET NOT RECOMMENDED
MINIMUM gAUgE EXTENSION CORd 
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
  Ampere 
 
Total Length 
gauge of 
 
Rating 
Volts 
of Cord in Feet 
Extension Cord
 
0-6 
240 
up to 50 
18 AWg 
  0-6 
240 
50-100 
16 AWg 
  0-6 
240 
100-200 
16 AWg 
  0-6 
240 
200-300 
14 AWg
  6-10 
240 
up to 50 
18 AWg 
  6-10 
240 
50-100 
16 AWg 
  6-10 
240 
100-200 
14 AWg 
  6-10 
240 
200-300 
12 AWg      
  10-12 
240 
up to 50 
16 AWg 
  10-12 
240 
50-100 
16 AWg 
  10-12 
240 
100-200 
14 AWg 
  10-12 
240 
200-300 
12 AWg
  12-16 
240 
up to 50 
14 AWg 
  12-16 
240 
50-100 
12 AWg 
  12-16 
240 
GREATER THAN 100 FEET NOT RECOMMENDED
3.  
240 VOLT SINgLE PHASE OPERATION
 
The  motor  supplied  with  your  machine  is  a  dual 
voltage,  120/240  volt  motor.  It  is  shipped  ready-
to-run  for  120  volt  operation.  However,  it  can  be 
converted for 240 volt operation.
 
A qualified  electrician  should  do  the  conversion,  or 
the  machine  can  be  taken  to  an  Authorized  Delta 
Service Center. When completed, the machine must 
conform  to  the  National  Electric  Code  and  all  local 
codes and ordinances.
  
The  machine  is  converted  by  re-wiring  the  motor 
for 240 volts, installing a 240 volt plug on the power 
supply cord and replacing the switch with one that is 
rated for 240 volt operation.
 
  
Be  sure  the  240  volt  plug  is  only  used  in  an  outlet 
having the same configuration as the plug illustrated 
in  Fig.  C.  No  adapter  should  be  used  with  the  240 
volt plug. 
 
In  all  cases,  make  certain  that 
the  receptacle  in  question  is  properly  grounded. 
If  you  are  not  sure,  have  a  qualified  electrician
check the receptacle.