•  Install Air Filter Outer Element by pushing it into the 
housing.
•  Install the Air Filter Housing (5A) and close the three 
(3) Air Filter Housing Clamps (5A).
The three (3) Air Filter Housing Clamps (5A) 
can NOT be closed unless the Air Filter Outer 
Element is properly installed.
•  Replace the Inner Safety Element once per year or if 
it becomes damaged.
•  Replace any damaged filters or gaskets.
•  Check air hose and clamps for damage or looseness.  
Tighten or replace as required.
Wheels and Hubs:
•  Check  for  excess  wear  and  looseness. Tighten  or 
replace as required.
FUEL FILTER :
•  Replace Spin-On Fuel Filter (5F) every 500 hours.
11 
Blade Shaft V-Belt Tension
(See Figures 1-3)
This saw is equipped with high tension banded V-belts. 
The belts are properly tensioned at the factory but after 
a few hours of operation they will stretch and become 
loose. Re-tension belts as described below.
To Tension V-Belts: 
•  Turn  ENGINE  START  SWITCH  (1H)  to  the  “0”  
(OFF) position.
•  Open  ENGINE  HOOD  (6E):  See  Figure(s)  3-1/3-2, 
Item 3-1D/3-2D for procedure.
•  Using  the  BLADE  SHAFT  WRENCH  (2J),  loosen  
the  horizontal  clamping  bolts  (3K)  at  the  front  of  
the machine.
•  Turn each of the two (2) vertical BELT TENSIONING 
BOLTS (3-1J, 3-2J) [at the front of machine, below the 
ENGINE GEARBOX (3-1A, 3-2A)] CLOCKWISE until 
the V-BELTS (3-1M, 3-2M) are tight.
•  Replace V-BELTS (3-1M, 3-2M) in complete sets only. 
•  For optimum V-Belt tension use Goodyear TensionRite™ 
Strips, P/N 542 19 13-68. TensionRite™ strips are sup-
plied with belts purchased from your dealer. 
•  Never  tension  V-BELTS  (3-1M,  3-2M)  beyond  the  
original  factory  tension.  Loose  V-Belts  result  in  poor 
saw performance and short belt life.
Replace all shields and guards. Never run Saw 
with out all shields and guards in place. 
12 
Hydraulic System
(See Figures 1-6)
The  hydraulic  system  on  this  saw  is  used  to  RAISE/ 
LOWER  the  Diamond  Blade  (2E),  and  to  propel  the 
saw FORWARD and REVERSE. The hydraulic system 
consists of a Hydrostatic Pump (5N), (2) Hydraulic Wheel 
Motors (4F), Hydraulic Filter (5K), DC Lift Pump (5H), 
Hydraulic Oil Reservoir (5J), Flow Control Valve (1U), 
and Hydraulic Lift Cylinder (4G).
• 
Hydraulic  Filter  (5K)  should  be  changed  after  the 
first 50 hours of operation, then every 250 hours of 
operation.
• 
Check Hydraulic Reservoir (5J) fluid level periodically.  
Maintain oil level with SAE 15W40 API Class SE, CC, 
CD  motor  oil. 
DO  NOT  OVERFILL,  check  oil  level 
when saw is level.
• 
Change hydraulic fluid every 500 hours of operation. 
Fill Hydraulic Reservoir (5I,5J) with approximately 2.5 
quarts of SAE 15W40 API Class SE, CC, CD motor 
oil. 
DO NOT OVERFILL! Check oil level when saw  
is level.
• 
The lowering rate of the saw can be adjusted using 
the Flow Control Valve (1U) at the rear of the saw. If 
the saw falls too quickly, turn the knob on the Flow 
Control Valve (1U) CLOCKWISE until an adequate 
lowering rate is set.
13 
Important Advice
(See Figures 2-3)
• 
Tighten loose nuts and bolts regularly, particularly after 
several hours of operation.
• 
Check  V-Belt  (3-1M,  3-2M)  tension  regularly.  
Re-tighten V-Belts (3-1M, 3-2M) as necessary.
• 
Remove the Diamond Blade (2E) for storage. Store  
it carefully.
• 
Check the water spray over the Diamond Blade (2E) 
periodically.
• 
Tighten the Diamond Blade (2E) firmly on the Blade 
Arbor (2C).
• 
Make sure the contact faces of Flanges (2B & 2F), 
Diamond Blade (2E), and Blade Shaft (2I) are clean.
Store in a safe place out of reach of children.  
Remove all adjustment tools and wrenches.  
Store  diamond  tool  in  a  safe  place  so  it 
cannot be damaged.