Intel SRCSAS144E ユーザーズマニュアル

ページ / 28
17
Intel® RAID Controller SRCSAS144E Hardware Guide
Thermal and Atmospheric Characteristics
The thermal and atmospheric characteristics are:
• Relative humidity range: 5% to 90% non-condensing
• Maximum dew point temperature: 32° C
• Airflow must be at least 300 linear feet per minute (SFPM) to avoid operating the 
80333 processor above the maximum ambient temperature
The storage and transit environment conditions are:
• Temperature range from -30° C to 80° C (dry bulb) without battery, 0° C to 45° C (dry 
bulb) with battery.
• Relative humidity range: 5% to 90% non-condensing
Safety Characteristics
The RAID Controller SRCSAS144E meets or exceeds the requirements of UL 
flammability rating 94 V0. Each bare board is also marked with the supplier name or 
trademark, type, and UL flammability rating. For the boards installed in a PCI Express* 
bus slot, all voltages are lower than the SELV 42.4 V limit.
The design and implementation minimizes electromagnetic emissions, susceptibility to 
radio frequency energy, and the effects of electrostatic discharge. The adapter carries the 
CE mark, C-tick mark, FCC self-certification logo, Canadian compliance statement, 
Korean MIC, Taiwan BSMI, and Japan VCCI. The adapter meets the requirements of 
CISPR Class B. Both the adapter and battery are CCSA C22.2, No. 60950-1, UL60950-1 
First Edition listed accessory, UL filenumber E257743.