Graco Inc. 295533 ユーザーズマニュアル

ページ / 34
Spray Pattern Adjustment 
16
311320G
e. If buildup recurs shortly after cleaning 
tip, remove air cap and ensure inside is 
clean.
Reinstall air cap and ensure airflow is properly 
set.
If no buildup occurred on air cap, check the fol-
lowing items in this order and readjust if neces-
sary:
Check Valving Rod Adjustment 
Screw/Sleeve setting.
Check hose temperature setting.
Check primary heater temperature setting.
Ensure spray pressures between chemi-
cals are balanced. If they are not, refer to 
Troubleshooting section of Proportioning 
Unit Operation Manual for the proportioner 
in use.
Ensure flow of air to air cap is adequate but 
not excessive.
Table 1: Valving Rod Adjustment for Standard Mixing Chambers
Chamber
Turns Out From Point of 
Valving
Recommended 
Distance of Gun 
from Surface
Pattern Size
Minimum
Maximum
46-800
1/2 turn
2 turns
12 in. (304-8 mm)
6 in. (152.4 mm)
46-810
1/2 turn
2 turns
12 in. (304-8 mm)
6 in. (152.4 mm)
55-776
1 3/4 turns
2 5/8 turns
18 to 20 in. (457.2 
to 508 mm)
8 in. (203.2 to 
228.6 mm)
62
2 turns
3 turns
18 to 20 in. (457.2 
to 508 mm)
8 to 9 in. (203.2 
to 228.6 mm)
70
2 turns
3 turns
18 to 20 in. (457.2 
to 508 mm)
10 to 12 in. (254 
to 304.8 mm)
78-851
2 turns
3 turns
24 in. (609.6 mm)
14 in. (355.6 mm)