Graco Inc. 311911C ユーザーズマニュアル

ページ / 40
Spin Test 
16
311911C
Spin Test
See Wiring Diagram, page 36.
To check armature, motor winding and brush electrical 
continuity:
1.
Relieve pressure, page 7. Disconnect power cord 
from outlet.
2.
Remove two screws (30) and shroud (29).
3.
Remove drive housing (5), page 15.
4.
Disconnect motor connector (F).
Armature Short Circuit Test
Quickly turn motor fan by hand. If motor coasts two or 
three revolutions before complete stop, there are no 
electrical shorts. If motor does not spin freely, armature 
is shorted. Replace motor, page 34.
Armature, Brushes, and Motor Wiring Open 
Circuit Test (Continuity)
1.
Connect red and black motor leads with test lead. 
Turn motor fan by hand at about two revolutions per 
second.
2.
If uneven or no resistance, check for missing brush 
caps, broken brush springs, brush leads, and worn 
brushes. Repair as needed, page 18.
3.
If still uneven or no resistance, replace motor, page 
34.
4.
Reattach motor connector (F).
5.
Replace drive housing, page 15.
6.
Replace shroud (29) and two screws (30).
29
30
F
F
FinishPro 390
FinishPro 395
ti5638a
ti2572b