Service 
8
312388K
Service
Preparation
1. Flush and clean gun before servicing.
2. Follow Pressure Relief Procedure,
Air Cap, Nozzle, and Needle
1. Unscrew air cap (1).
2. Trigger gun while you remove the 
nozzle (2) with gun tool (27).
3. Remove fluid adjustment knob (8-2) and 
spring (9).
4. Pull fluid needle (10) out the back of the 
gun.
Air Valve and Needle Packings
1. Remove retaining rings (15), pin (16), and 
trigger (17).
2. Remove packing nut (4) and fluid needle 
packings (3-1, 3-2).
3. Remove fluid needle guide (7).
4. Remove fluid adjusting guide (8-1).
5. Remove spring (18) and air valve (19).
6. Remove air valve seat (20) and o-rings. 
7. Replace parts as needed.
8. Assemble gun in reverse order. Lubricate 
needle and o-rings. Be sure to trigger gun 
when installing nozzle (2).
Fluid leaking from 
packing nut (4).
a. Packing nut (4) loose.
a. Tighten, but not so tight as to grip
needle.
b. Packing (3-1, 3-2) worn or 
dry.
b. Lubricate or replace.
Fluid nozzle (2)
dripping.
a. Dry packing (3-1, 3-2).
a. Lubricate.
b. Sluggish needle (10).
b. Clean and lubricate.
c. Packing nut (4) too tight.
c. Loosen.
d. Worn fluid nozzle or 
needle.
d. Replace.
Thin, coarse finish.
a. Gun held too far from 
surface.
a. Hold gun about 6 to 8 inches 
(150 to 200 mm) from surface.
b. Atomization air pressure 
set too high.
b. Reduce air pressure.
Thick, dimpled finish 
(resembling orange 
peel).
Gun held too close to surface. Hold gun about 6 to 8 inches 
(150 to 200 mm) from surface.
Problem
Cause
Solution
Trigger gun and use gun tool (27) when-
ever you tighten or remove the nozzle (2) 