Relief Valve and Flow Sensor Manifold
310645K
25
Relief Valve and Flow Sensor Manifold
For 120 V sprayer use Relief Valve Replacement Kit 
287325.
For 230 V sprayer use Relief Valve Replacement Kit 
287350.
Disassembly
First read and follow instructions in the Before 
performing any service on sprayer
 section, page 9.
Then remove hopper, front and back covers, page 9.
1 Remove air line to 
regulator.
2  Remove air line from 
cooler to manifold.
3  Disconnect wires to Relief Valve. Pay attention to their 
location to insure they are reattached correctly.
4  Remove 2 nuts securing 
Relief Valve to sprayer.
5  Remove Relief Valve 
from sprayer frame.
Reassembly
1 Position new relief valve from Kit in back of sprayer.
2  Replace and tighten screws.
3 Reattach wires to Relief Valve.
4  Reattach air line from cooler to manifold.
5  Reattach air line to regulator.Replace RotoFlex HD 
Pump and hose extension, page 12.
6  Replace front cover and hopper. See Removing and 
Replacing Hopper, Front and Back Cover, page 9.
ti4423a
ti4418a