Hitachi RTX 900 ユーザーズマニュアル

ページ / 34
Motor 
18
311772G
Reassembly
1.
Angle motor pulley through compressor belt (84) 
and pull motor (71) into position. 
2.
Tighten two mounting bolts (105) on motor (71) until 
snug, then back 1/8 of a turn.
3.
Insert torque wrench into square hole (SQ) on motor 
and tighten bolts to 130-150 in-lb (this may require 
two people; one to torque while the other tightens 
mounting bolts). Tighten motor bolts (105).
4.
Take compressor out of vice and rotate pump pulley 
(104) one full revolution to seat the belt properly.
5.
Place compressor back into vice and torque bolts as 
described in steps 2 and 3. 
6.
Replace fan (72) and tighten set screw.
7.
Replace Compressor; page 12.
8.
Replace RotoFlex
 II Pump hose; page 9 or 10.
9.
Replace Shroud, page 7.
When replacing motor (71), make sure the 
square-shaped hole (SQ) is facing toward the out-
side of the compressor. This hole will be used to 
torque the mounting bolts.
SQ
ti8890a
71
84
ti8891a
105
71
ti8896a
104
ti8892a
72