OPERATOR’S MANUAL
635043
RELEASED:
9-8-83
REVISED:
7-7-00
(REV. B)
ARO STOP
R
OPERATION, INSTALLATION & MAINTENANCE
635043
PUMP SAVER CONTROL VALVE - 3/4” PIPE SIZE
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
GENERAL DESCRIPTION
This device is to terminate operation of an 8" to 12" reciprocating type
air motor in the event of a ruptured outlet hose or the pump runs out of
media. For compressed air use only.
Operating Pressure Range
30 Ć 120 p.s.i. (2.1 Ć 8.3 bar)
. . .
Temperature Range
0_ to 180_F(Ć18_ to 82_C)
. . . . . . . . .
OPERATION
The AROĆSTOP control valve senses an increased volume of air to the
pump, beyond the preadjusted setting, and shuts off the air supply to
the pump. The runaway" condition may be caused by any of the followĆ
ing: 1.) depleted pump material, 2.) a ruptured line on the outlet of the
pump, 3.) excessive cavitation in the material supply.
INSTALLATION
The AROĆSTOP valve should be installed in a filtered and regulated air
line. The Filter & Regulator should be no smaller than an Aro HeavyĆ
Duty series. Upstream plumbing from the AROĆSTOP should be 3/4"
minimum. The 3/4" swivel furnished with the AROĆSTOP is to be
installed on the inlet of the AROĆSTOP to facilitate easy adjustment.
Install the outlet of the AROĆSTOP on the inlet of pump motor. InstallaĆ
tion of AROĆSTOP as illustrated is recommended. Use one AROĆSTOP
for each pump. See typical installation photo.