Multiquip 8FP Series ユーザーズマニュアル

ページ / 74
 
 
 
ASSEMBLY INSTRUCTIONS/OPERATIONS
8FP FLOOR PLANER SERIES 
OPERATION AND PARTS MANUAL REV #2 (05/28/09) 
PAGE 27 
 
DANGER
 
 
AS SOON AS THE ELECTRIC MOTOR HAS 
STARTED, THE OPERATOR MUST BE IN A 
POSITION TO ASSUME DIRECT AND FULL 
CONTROL OF THE FLOOR PLANER. FAILURE TO 
ASSUME DIRECT AND FULL CONTROL CAN 
RESULT IN PROPERTY DAMAGE AND/OR 
PERSONAL INJURY. 
10) The 8FP/E Series electrically powered Floor 
Planer is stopped by moving the ON/OFF switch 
located on the operator handle to the OFF position. 
For safety considerations, it is recommended that the 
extension cord be disconnected from both the Floor 
Planer  and electric power source whenever the Floor 
Planer is not in use on the jobsite. 
 
STARTING THE 8FP/G SERIES GASOLINE 
POWERED FLOOR PLANER ON THE JOBSITE. 
 
1) Position the Floor Planer on a flat and level surface 
of firm foundation. 
 
2) Rotate the height adjustment lever 
counterclockwise to raise the Floor Planer to its 
maximum position above the work surface. This will 
insure proper clearance between the loaded drum and 
the work surface. 
 
DANGER
 
 
DO NOT ATTEMPT TO START THE ENGINE 
WITHOUT FIRST DETERMINING THAT THE 
LOADED DRUM IS NOT IN CONTACT WITH THE 
WORK SURFACE. IF THE ROTATING FLAILS 
COME IN CONTACT WITH THE WORK SURFACE 
BEFORE THE OPERATOR HAS ASSUMED FULL 
CONTROL, THE ACTION HAS THE POTENTIAL TO 
PULL THE FLOOR PLANER AWAY. A RUNAWAY 
FLOOR PLANER CAN CAUSE PROPERTY 
DAMAGE AND/OR PERSONAL INJURY. 
 
3) Refer to the material supplied by the engine 
manufacturer for the correct starting, operation  and 
stopping procedures. 
 
4) Allow the engine to properly "warm up" and operate 
without the requirement for choking. Check for 
excessive machine noise and/or vibration. 
 
DANGER
 
DO NOT OPERATE A GASOLINE ENGINE IN 
CLOSED SPACES WITHOUT PROPER 
VENTILATION. GASOLINE ENGINES PRODUCE 
CARBON MONOXIDE FUMES. BREATHING 
CARBON MONOXIDE FUMES CAN RESULT IN 
PROPERTY DAMAGE AND/OR PERSONAL 
INJURY.  EXCESSIVE LEVELS OF CARBON 
MONOXIDE CAN CAUSE DEATH. 
 
5) Stop the engine in accordance with the instructions 
as described in the material supplied by the engine 
manufacturer. 
 
CAUTION
 
 
If the Floor Planer and/or an individual 
component/accessory does not appear to be 
functioning properly, STOP and do not further 
operate the Floor Planer until the proper corrective 
action has been completed. If there are any 
questions regarding the proper operation of the 
Floor Planer, contact the Customer Service 
Department BEFORE further utilization. There is 
no charge for this service. 
 
OPERATING THE FLOOR PLANER ON THE JOB 
SITE. 
 
Application: All Models. 
 
DANGER
 
 
THE PLANING PROCESS PRODUCES EXCESSIVE 
NOISE, VIBRATION AND FLYING DEBRIS. ALL 
OPERATORS AND WORK PERSONNEL IN THE 
VICINITY OF THE FLOOR PLANER MUST WEAR 
APPROPRIATE SAFETY EYE WEAR AND 
HEARING PROTECTION DEVICES. OTHER 
SAFETY APPAREL AND/OR PROCEDURES, 
DEEMED NECESSARY BY SUPERVISORY 
PERSONNEL MUST ALSO BE WORN  AND/OR 
PRACTICED BY ALL APPROPRIATE PERSONNEL. 
 
DANGER
 
 
EXERCISE EXTREME CAUTION WHEN 
OPERATING THE FLOOR PLANER IN THE 
VICINITY OF DECK INSERTS, PIPES, COLUMNS, 
OPENINGS, LARGE CRACKS, UTILITY OUTLETS 
OR ANY OBJECT PROTRUDING FROM THE 
SURFACE. CONTACT WITH SUCH OBJECTS CAN 
LEAD TO LOSS OF MACHINE CONTROL, 
RESULTING IN PROPERTY DAMAGE AND/OR 
PERSONAL INJURY.