Hitachi NT 65MA4 (S) ユーザーズマニュアル

ページ / 68
16
English
15 
Disconnect air 
hose
Adjuster
If nails are driven too shallow, turn the adjuster 
to the deep side.
3
  Stop turning the adjuster when a suitable 
position is reached for a nailing test.
4
  Connect the air hose.
 
ALWAYS WEAR SAFETY GLASSES.
 
Perform a nailing test.
5
  DISCONNECT AIR HOSE FROM NAILER.
6
  Choose a suitable position for the adjuster.
Too Deep
Too Shallow
Turn Adjuster
Turn Adjuster
Flush
Flush
2
2
Using the blow nozzle
WARNING 
 
● Be sure to release your fi nger from 
the trigger before using the blow 
nozzle.
 
● Do not point the air outlet at a 
person.
 
● Do not use the blow nozzle with the 
push lever left fi t.
This Nailer has a blow nozzle that blows out 
wood shavings which occur during work.
Press the knob with your thumb to use the blow 
nozzle, as shown in the fi gure.
Knob
Air outlet
NOTE
 
● When the blow nozzle is used for a long time, 
the nailing force may degrade temporarily. 
In this case, allows the air supply pressure 
to stabilize before starting work.
 
● Oil in the body or drained water from the 
compressor can sometimes spout out 
of the air outlet. It is recommended that 
you once conduct a test before use and 
see if such phenomenon happens at an 
environment where spouted oil will cause 
any inconvenience.
Changing the exhaust direction
WARNING 
 
● When changing the exhaust 
direction, be sure to remove 
your  fi nger from the trigger and 
disconnect the air hose from the 
nailer.
The direction of the exhaust vent can be 
changed by turning the top cover.
Exhaust 
Vent
Top Cover
000Book_NT65MA4(S)_US.indb   16
000Book_NT65MA4(S)_US.indb   16
2010/11/24   9:04:30
2010/11/24   9:04:30