Southbend SB1013 ユーザーズマニュアル

ページ / 80
For Machines Mfg. Since 7/09
EVS Toolroom Lathes
-15-
P R E P A R A T I O N
In addition to the gearboxes, we also recommend 
that you lubricate all other points on the 
machine at this time. This can be accomplished 
by following the maintenance schedule on Page 
54
.
Note:
 If your lathe was shipped with oil in the 
gearboxes, do not change that oil until after the 
break-in period.
Power Connection
Electrocution or fire 
may occur if machine is 
ungrounded, incorrectly 
connected to power, or 
connected to an undersized 
circuit. Use a qualified 
electrician to ensure a safe 
power connection.
Once all preparation steps previously described 
in this manual have been completed, the 
machine can be connected to the power source. 
In order to be connected to the power source, a 
circuit must be installed/prepared that meets 
the requirements of the lathe, and a power 
connection method must be established for that 
circuit. The following lists show the minimum 
requirements for each model, and instructions 
follow for each connection method.
Note About Power Cords: Using an incorrectly 
sized cord causes electrical components on 
the machine and the cord to become very hot, 
which will greatly decrease the life of electrical 
components or result in fire. For best results, 
use the shortest length of cord possible for your 
machine, and never use a smaller cord gauge 
than the specified minimum.
This machine is equipped with a frequency 
drive that contains sensitive electronics, 
which can be damaged by a phase converter. 
DO NOT use a phase converter to power this 
machine. Doing so will void the warranty.
Adding Cutting Fluid
Add the cutting fluid of your choice now. For 
detailed instructions on where the cutting fluid 
tank is located and how to add fluid, refer to 
Cutting Fluid System on Page 62.
SB1012 (220V 3-Phase)
Full Load Amp Draw ............................ 15.7 Amps
Phase ..........................................................3-Phase
Frequency ...................................................... 60  Hz
Minimum Circuit Size ............................. 20 Amps
Recommended Plug/Receptacle ......NEMA L15-20
Minimum Cord Size .......... 12 AWG, 4-Wire, 300V
Maximum Cord Length ................................. 50 ft.
SB1014, SB1037 (220V 3-Phase)
Full Load Amp Draw ............................ 21.7 Amps
Phase ..........................................................3-Phase
Frequency ...................................................... 60  Hz
Minimum Circuit Size ............................. 30 Amps
Recommended Plug/Receptacle ......NEMA L15-30
Minimum Cord Size ............ 8 AWG, 4-Wire, 300V
Maximum Cord Length ................................. 50 ft.
SB1013 (440V 3-Phase)
Full Load Amp Draw ............................ 7.75 Amps
Phase ..........................................................3-Phase
Frequency ...................................................... 60  Hz
Minimum Circuit Size ............................. 15 Amps
Recommended Power Connection ........ Hardwire*
SB1015, SB1038 (440V 3-Phase)
Full Load Amp Draw .......................... 10.75 Amps
Phase ..........................................................3-Phase
Frequency ...................................................... 60  Hz
Minimum Circuit Size ............................. 15 Amps
Recommended Power Connection ........ Hardwire*
* Hardwire setups must include a locking 
disconnect switch between the power source and 
the lathe. Refer to Page 16 for more details.