460V, 50/60Hz, 3-Phase 
 
Inductance (mH) 
kW HP 
Fundamental 
Amps 
Max. 
continuous 
Amps 
3% impedance
 
5% impedance 
0.4 1/2 
20 
32 
0.75 1 
12 
1.5 2 
6.5 
2.2 3 
12 
7.5 
 
B.3.2 AC Output Reactor Recommended Value 
115V/230V, 50/60Hz, 3-Phase 
 
Inductance (mH) 
kW HP 
Fundamental 
Amps 
Max. 
continuous 
Amps 
3% impedance
 
5% impedance 
0.2 
1/4 4 
12 
0.4 
1/2 6 
6.5 
0.75 
1 8 
12 
1.5 
2 8 
12 
1.5 
2.2 
3 12 
18 
1.25 
2.5 
 
460V, 50/60Hz, 3-Phase 
 
Inductance (mH) 
kW HP 
Fundamental 
Amps 
Max. 
continuous 
Amps 
3% impedance
 
5% impedance 
0.4
 
1/2 2 
20 
32 
0.75 
4 6  9 
12 
1.5 
4 6  6.5 
2.2 
8 12  5 
7.5 
 
B.3.3 Applications for AC Reactor 
Connected in input circuit 
 
Application 1 
Question 
When more than one AC motor drive is 
connected to the same mains power, and one 
of them is ON during operation. 
When applying power to one of the AC motor 
drive, the charge current of the capacitors 
may cause voltage dip. The AC motor drive