Impinger II – Installation & Operation Manual 
5
UTILITY SPECIFICATIONS REQUIRED – ELECTRIC
 
 
*Model 
Energy 
Power 
Voltage 
Current 
Phase 
Hz 
Recommended 
Electrical Specification 
1130-xxx-E-Kxxx 
Electric 
10kW 
120/208V 
48 Amps 
60 Hz 
4 Wires, 2 Pole + N + G 
1131-xxx-E-Kxxx 
Electric 
10kW 
120/240V 
42 Amps 
60 Hz 
4 Wires, 2 Pole + N + G 
1132-xxx-E-Kxxx 
Electric 
10kW 
120/208V 
28 Amps 
60 Hz 
5 Wires, 3 Pole + N + G 
1133-xxx-E-Kxxx 
Electric 
10kW 
120/240V 
25 Amps 
60 Hz 
5 Wires, 3 Pole + N + G 
1151-xxx-E-Kxxx 
Electric 
10kW 
200V 
29 Amps 
50/60 Hz 
4 Wires, 3 Pole + G 
1161-xxx-E-Kxxx 
Electric 
10kW 
120/240V 
42 Amps 
60 Hz 
4 Wires, 2 Pole + N + G 
1162-xxx-E-Kxxx 
Electric 
10kW 
120/208V 
28 Amps 
60 Hz 
5 Wires, 3 Pole + N + G 
1164-xxx-E-Kxxx 
Electric 
10kW 
400V 
42 Amps 
50 Hz 
5 Wires, 3 Pole + N + G 
 
 
* REFERENCE MODEL NUMBER KEY 
  
UTILITY SPECIFICATIONS REQUIRED – GAS 
 
Model 
Energy 
Power 
Voltage 
Current 
Phase 
Hz 
Recommended 
Electrical Specification 
Gas 
1116-xxx-E-Kxxx 
Nat. Gas 
40,000 BTU 
120 VAC 
7 Amps 
60 Hz 
3 Wires, 1 Pole + N + G 
40,000 BTU at 7 inches, 
H
2
O column** 
1117-xxx-E-Kxxx 
L.P. Gas 
40,000 BTU 
120 VAC 
7 Amps 
60 Hz 
3 Wires, 1 Pole + N + G 
40,000 BTU at 11 inches, 
H
2
O column** 
1154-xxx-E-Kxxx Nat. 
Gas H
s
 13 KW 
230 VAC 
2 Amps 
50 Hz 
3 Wires, 1 Pole + N + G 
H
s
 13 KW/HR at 1.7 kPa, 
H
2
O column** 
1155-xxx-E-Kxxx L.P. 
Gas H
s
 13 KW 
230 VAC 
2 Amps 
50 Hz 
3 Wires, 1 Pole + N + G 
H
s
 13 KW/HR at 2.73 
kPa, H
2
O column** 
1178-xxx-E-Kxxx 
Nat. Gas 
40,000 BTU 
120 VAC 
7 Amps 
60 Hz 
3 Wires, 1 Pole + N + G 
40,000 BTU at 7 inches, 
H
2
O column** 
 
 
GAS PRESSURE CONVERSION CHART 
Inches of 
Water Column 
KPa m-Bar 
Millimeters of 
Water Column 
3.5 0.87 
8.70 
88.9 
4.5 1.12 
11.2 
114.3 
7 1.74 
17.40 
177.8 
10 2.48 
24.87 
254.0 
10.5 2.61 
26.11 
266.7 
11 2.73 
27.36 
279.4 
14 3.48 
34.81 
355.6 
14.5 3.61 
36.05 
368.3 
** NOTE:  For proper operation, the gas valve requires a nominal inlet pressure of 7 
inches of H
2
O for natural gas and 11 inches of H
2
O column for L.P. gas.  A minimum 
inlet pressure of 1.0 inch of H
2
O column above the manifold setting (NAT. manifold 
3.5” H
2
O, L.P. manifold 10” H
2
O) must be maintained with no pressure drop from the 
no load to full load condition.  The maximum inlet pressure must be maintained at or 
below ½ PSIG (14.5 inches H
2
O column).  Refer to the chart on the left for pressure 
conversions. 
 
Electrical Supply for Australia: 
Single Phase:  240 VAC, 50 Hz / 20 Amp; one neutral & one earth/ground. 
Three Phase:  240/415 VAC / 20 Amp; three active, one neutral & one earth/ground. 
 
All ovens require separate service and dedicated neutral. 
 
NOTE:  Do not install the (these) oven(s) in any area with an ambient temperature in 
excess of 95°F / 35° C.  Doing so will cause damage to the unit.