Maytag MER6751AAB/Q/S/W ユーザーズマニュアル

ページ / 85
Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless  
testing requires power. 
 
©2004 Maytag Services 
16023416 
15 
Component Testing 
Illustration Component 
Test 
Procedure 
Results 
 
 
 
Oven light socket 
Remove one wire from receptacle and 
test resistance of terminals ..................
Measure voltage at oven light ..............
 
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal 
identification. 
If no voltage is present at oven light, 
check wiring or light switches. 
4-turn 
5-turn 
(Model MER6555AA*) 
Coil elements 
Remove element and measure 
resistance across terminals. ................ 
Continuity, if not replace. 
4-turn: 
37 to 45 
Ω Approximately 
5-turn: 
23 to 27 
Ω Approximately 
1200 W 
2500 W 
Ribbon elements 
Remove element and measure 
resistance across terminals. ................ 
Continuity.  If not, replace. 
1200W:  45 to 49 
Ω Approximately 
2500W:  20 to 24 
Ω Approximately 
2400 W/1100 W (Dual) 
2700 W/1700 W (Dual) 
(Models MER6775AA*, 
MER6875AA*) 
Ribbon elements 
Remove element and measure 
resistance across terminals. ................ 
Continuity.  If not, replace. 
1100W:  40 to 46 
Ω Approximately (Inner) 
1300W:  47 to 54 
Ω Approximately (Outer) 
1700W:  30 to 36 
Ω Approximately (Inner) 
1000W:  53 to 59 
Ω Approximately (Outer) 
2700 W (Single) 
(Model MER6755AA*) 
Ribbon elements 
Remove element and measure 
resistance across terminals. ................ 
Continuity.  If not, replace. 
2700W:  19 to 23 
Ω Approximately 
100 W (Warmer) 
(Models MER6775AA*, 
MER6875AA*) 
Ribbon elements 
Remove element and measure 
resistance across terminals. ................ 
Continuity.  If not, replace. 
100W: 
132 to 146 
Ω Approximately 
 
L2
L1
H2
P
H1
1
2
3
4
5
 
Snap Action Infinite 
switch 
Connect Volt-ohms meter to  
H1 and H2. 
 
Measure the following for voltages at 
LO, MED, HI: 
  H1 to H2 ............................................ 
                      Approximate 
                
 Time On 
Time Off 
LO 5% 
 
95% 
MED (4-5) 
35% 
 
65% 
HI 100% 
 
0% 
240 VAC, if not replace switch. 
 
 
Bake element, Upper 
Disconnect wire leads to element and 
measure resistance of terminals ..........
Measure voltage at bake element ........
 
Approximately 31.0 
Ω
, if not replace. 
240 VAC, see wiring diagram for terminal 
identification. If no voltage is present at 
bake element check wiring. 
 
 
Bake element, Lower 
Disconnect wire leads to element and 
measure resistance of terminals ..........
Measure voltage at bake element ........
 
Approximately 21.3 
Ω
, if not replace. 
240 VAC, see wiring diagram for terminal 
identification. If no voltage is present at 
bake element check wiring. 
 
 
Broil element, Upper 
Disconnect wire leads to element and 
measure resistance of terminals ..........
Measure voltage at broil element .........
 
Approximately 25.4 
Ω
, if not replace. 
240 VAC, see wiring diagram for terminal 
identification. If no voltage is present at 
broil element check wiring. 
 
 
Broil element, Lower 
Disconnect wire leads to element and 
measure resistance of terminals ..........
Measure voltage at broil element .........
 
Approximately 18.6 
Ω
, if not replace. 
240 VAC, see wiring diagram for terminal 
identification. If no voltage is present at 