Maytag MGR6875ADB/Q/S/W ユーザーズマニュアル

ページ / 69
Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
 
©2004 Maytag Services 
16023415 
23 
Component Test 
Procedure 
Results 
Electronic 
range control 
F1
1 –Upper Oven >650°F with door unlocked .............................
 
F1
2 –Lower Oven >650°F with door unlocked .............................
 
F1
3 –Upper Oven >950°F with door locked .................................
 
F1
4 –Lower Oven >950°F with door locked .................................
 
F1
7 –Membrane switch is not responding ...................................
 
F3
1 –Upper sensor is shorted at (< 100 Ω) or 
 
open at (>5 K 
Ω) ...............................................................
F3
2 –Lower sensor is shorted at (< 100 Ω) or 
 
open at (>5 K 
Ω) ...............................................................
Check actual upper oven temperature, 
if > 650
°F check sensor. 
Check actual lower oven temperature, 
if > 650
°F check sensor. 
Check actual upper oven temperature, 
if > 950
°F check sensor. 
Check actual lower oven temperature, 
if > 950
°F check sensor. 
Check membrane switch for connection or damage. 
 
 
Check upper sensor, harness, and connections 
 
Check upper sensor, harness, and connections 
Engineering 
Test Mode 
Press 
BAKE pad. 
Enter 100°F using the number pads. 
Immediately push and hold 
BAKE pad for appropriate oven 
approximately 3 seconds. 
This mode can also be entered by pressing the hidden pad 
for 3 second located to the left of the lower oven light pad. 
Used to view the actual oven temperature for both ovens at all 
times, even when an oven function is active. 
This mode will also display the current fault code for 5 
seconds in the time digits. 
Fault codes 
accessed 
through 
Engineering 
Test Mode 
F0
–No fault.................................................................  
F1
5 –Upper hardware failure within control....................  
F1
6 –Lower hardware failure within control....................  
F1
8 –Shorted key in membrane switch..........................  
F1
9 –Internal communication errors within control.........  
F1
A –Upper latch switches............................................  
F1
B –Lower latch switches............................................  
F1
C –Upper door switch................................................  
F1
D –Lower door switch ................................................  
F1
E –Sensor input not calibrated ..................................  
F1
H –EEPROM error.....................................................  
F1
L –Temp in ovens are the same for long period ........  
F1
N –Internal voltage on control not working.................  
F9
1 –Upper lock switch is not correct ............................  
F9
2 –Upper unlock switch is not correct ........................  
F9
3 –Control does not see upper door lock ...................  
F9
4 –Lower lock switch is not correct ............................  
F9
5 –Lower unlock switch is not correct ........................  
F9
6 – Control does not see lower door lock...................  
EE –Control cannot read E-PROM. Unit will shut down. 
Default from factory 
Replace control 
Replace control 
Check membrane connection 
Replace control 
Check latch wire harness 
Check latch wire harness 
Check lock wire harness 
Check lock wire harness 
Verify sensor is operating properly 
Replace control 
Verify sensor is operating properly 
Replace control 
Check lock wire harness, and lock switch 
Check lock wire harness, and lock switch 
Check lock wire harness, and lock switch 
Check lock wire harness, and lock switch 
Check lock wire harness, and lock switch 
Check lock wire harness, and lock switch 
Disconnect power for 60 seconds. If EE reappears, replace ERC 
Test Mode 
This mode must be activated within the first 5 minutes of 
power up.
 
Press BROIL and CANCEL pad for approximately 3 seconds. 
 
If oven temperature is greater than 400°F, the Test Mode 
cannot be activated or will abort if active. 
 
Press and hold individual pads for 4 seconds to activate. 
 
Display will have dashes in all segments to indicate the mode is 
active. 
Upper Bake: Energizes upper bake element 
Lower Bake: Energizes lower bake element 
Upper Broil: Energizes upper broil element 
Convection Bake: Energizes convection fan 
Upper Oven Light: Energizes upper oven light 
Lower Oven Light: Energizes lower oven light 
Upper Clean: Energizes upper motorized door lock 
Lower Clean: Energizes lower motorized door lock 
Stop Time: Energizes Beeper 
Cook Time: Displays error codes 
Timer 1: Energizes ROM version 
Timer 2: Energizes EEPROM version 
Keep Warm: Cooling Fan 
Clock: All display segments light 
 
If functions do not perform as specified, replace ERC 
Oven 
temperature 
adjustment 
Push 
BAKE pad. 
Enter 550°F using the number pads. 
Immediately push and hold 
BAKE pad for appropriate oven 
approximately 3 seconds. 
To decrease or increase oven temperature. Push 
AUTO SET 
pad until negative or positive numbers appear. Oven can be 
adjusted from -35° to +35° F (-37.2° to + 1.6° C).  To avoid over 
adjusting oven, move temperature -5° F (2.7° C) each time. 
Push 
OVEN CANCEL button. 
While increasing or decreasing oven temperature, this does not 
affect self-cleaning temperature. 
 
Holds offset through power outage.