Lincoln 1600 ユーザーズマニュアル

ページ / 28
Low Profile – 1600-000-A Advantage Series Service Manual – Domestic 
TROUBLESHOOTING GUIDE 
 
GAS OVENS 
 
MODEL 1600-000-A / NATURAL GAS / 120 VAC / 60 HZ / 1 PHASE 
MODEL 1601-000-A / L.P. GAS / 120 VAC  / 60 HZ / 1 PHASE 
 
NOTE:  
 
When checking components on left side of unit, be sure to check for proper connections in power 
connector, (marked P. C. on Schematic Diagram.) located inside motor cover. 
SYMPTOM 
POSSIBLE CAUSE 
EVALUATION 
Incoming Power 
Supply 
Check breakers, reset if required. Check power plug to be sure 
it is firmly in receptacle. Measure the incoming power/call 
power company if needed.   
 
Main Fan Switch 
Check continuity between switch terminals. 
Fuse, 10 Amp 
Check, replace if necessary. 
Fuse Holder 
Check, replace if necessary. 
Fuse 3A 
Check, replace if necessary. 
Fuse holder 
Check, replace if necessary. 
Hi Limit Thermostat(s) 
Control Box 
Check for voltage on both sides of the switch.  Terminals are 
normally closed.  If open, reset and test oven for proper 
operation.  If thermostat will not hold and control box 
temperature is not exceeding 140°F (60°C), replace 
thermostat. 
Oven Power Relay 
Check for 120 VAC to the relay coil.  If voltage is not present, 
trace wiring back to the control box hi-limit.  If voltage is 
present, check to insure contacts are closing.  Check for 120 
VAC supplied to terminal #2 of the relay. 
Main Fan Motor 
Check for opens, shorts, or grounds.  WITH POWER OFF turn 
fan blade to check for locked rotor. 
Oven fan will not run 
Capacitor 
Check for shorts or grounds. 
WARNING:  Capacitor has a stored charge, discharge before 
testing. 
Incoming Power 
Check main circuit breakers, reset if required, call power 
company if needed. 
Main Fan Switch 
Check continuity between switch terminals 
Fuse 3 amp. 
Check, replace if necessary. 
Fuse Holder 
Check, replace if necessary. 
Hi Limit Thermostat(s) 
Control Box 
Check for voltage on both sides of the switch.  Terminals are 
normally closed.  If open, reset and test oven for proper 
operation.  If thermostat will not hold and control box 
temperature is not exceeding 140°F (60°C), replace 
thermostat. 
No control box cooling 
Cooling Fan(s) 
120 VAC should now be at the fan motor.  If voltage is present, 
check motors for shorts or opens.  WITH POWER OFF:  
Check for locked rotor. 
Incoming Power 
Supply 
Check circuit breakers, reset if required.  Call the power 
company if needed. 
Cooling Fan 
Thermostat(s) 
Check the cooling fan thermostat.  (Thermostat closes at 
120°F and opens at 100°F).  With the cooling fan thermostat 
preheated, check for continuity.  If switch is open, replace. 
Fuse, 3 amp 
Check, replace if necessary 
Fuse Holder 
Check, replace if necessary 
No automatic control 
box cooling 
Hi Limit Thermostat(s) 
Control Box 
Check for voltage on both sides of the switch.  Terminals are 
normally closed.  If open, reset and test oven for proper 
operation.  If thermostat will not hold and control box 
temperature is not exceeding 140°F (60°C), replace 
thermostat.