Maytag MDB7600AWQ ユーザーズマニュアル
Component Specifications
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing,
unless testing requires power.
unless testing requires power.
May 2004
3
16023212
©2004 Maytag Services
Illustration Component
Test
Procedure
Results
Limit Thermostat
Close on Temperature drop @ 149°F
± 7°F (Temp) ......................................
Open on Temperature drop @ 164°F
± 4°F (Temp) ......................................
± 7°F (Temp) ......................................
Open on Temperature drop @ 164°F
± 4°F (Temp) ......................................
0
Ω = Closed
Infinite
Ω = Open
Sensor/Thermistor
10K
Ω ± 3% at 77°F and 2.4 k Ω ±
6.5% at 140°F
J5 pin 1 - Orange (Temp) to J5 Pin 4 -
Red (Neutral) .....................................
J5 pin 1 - Orange (Temp) to J5 Pin 4 -
Red (Neutral) .....................................
Infinite
Ω = Open
0
Ω = Closed
Heater/Heating
Element
120v/60hz, 650 watts
± 5% in air, 830 watts
± 5% in coldwater
Element
120v/60hz, 650 watts
± 5% in air, 830 watts
± 5% in coldwater
Measure resistance from ST1
Red/Black (Heater) to ST11 White
(Common) ..........................................
Red/Black (Heater) to ST11 White
(Common) ..........................................
16
Ω
(This value assumes the high limit
thermostat is closed).
thermostat is closed).
Drain Motor
120v/60hz
120v/60hz
Measure resistance from
ST6 Gray (Drain) to ST4 Black
(Common) ..........................................
See section “Motor Connections and
Diagram” for wiring contacts.
ST6 Gray (Drain) to ST4 Black
(Common) ..........................................
See section “Motor Connections and
Diagram” for wiring contacts.
25
Ω