Maytag MDB7600AWQ ユーザーズマニュアル

ページ / 8
Component Specifications 
!
WARNING
 
To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, 
unless testing requires power. 
 
May 2004 
16023212 
©2004 Maytag Services 
 
Illustration Component 
Test 
Procedure 
Results 
 
 
Limit Thermostat 
 
Close on Temperature drop @ 149°F 
± 7°F (Temp) ......................................
Open on Temperature drop @ 164°F 
± 4°F (Temp) ......................................
 
 
Ω          = Closed 
 
Infinite 
Ω = Open 
 
 
 
Sensor/Thermistor 
 
10K
Ω ± 3% at 77°F and 2.4 k Ω ± 
6.5% at 140°F 
 
J5 pin 1 - Orange (Temp) to J5 Pin 4 -
Red (Neutral)  .....................................
 
 
 
 
 
Infinite 
Ω = Open 
Ω          = Closed 
 
 
Heater/Heating 
Element 
 
120v/60hz, 650 watts 
± 5% in air, 830 watts 
± 5% in coldwater 
Measure resistance from ST1 
Red/Black (Heater) to ST11 White 
(Common) ..........................................
 
 
 
 
16 
Ω 
(This value assumes the high limit 
thermostat is closed). 
 
Drain Motor 
 
120v/60hz 
Measure resistance from  
ST6 Gray (Drain) to ST4 Black 
(Common) ..........................................
 
See section “Motor Connections and 
Diagram” for wiring contacts.  
 
 
25 
Ω