TROUBLESHOOTING & REPAIR
PRO-CUT 60
F-10
Observe Safety Guidelines
detailed in the beginning of this manual.
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
The "MACHINE ON" LED is lit
but there is no response when
the torch trigger is pulled.  The
"AIR PRESSURE" LED does
not turn on.  The fan runs nor-
mally.  The “FAULT” LED
blinks.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
1. Check the air supply to the
machine.  Make sure suffi-
cient air pressure is supplied
to the PRO-CUT 60.  If the
air does not flow, the
machine will not operate.
2. Low air pressure will also 
result in a "no start" condi-
tion.  With the machine in 
"PURGE" adjust the air reg-
ulator to 60 psi (413kPa) 
minimum while air is flowing.  
"AIR PRESSURE" LED 
must be lit when the air is 
flowing.
3. Check the operation of the 
air solenoid by switching the 
machine to "PURGE".  If the 
air pressure is sufficient the 
air should begin to flow and 
"AIR PRESSURE" LED 
should turn on.  Return to 
the "RUN" mode.  If air does 
not flow when the torch trig-
ger pulled, consult your local 
Lincoln Authorized Field 
Service Facility.
4. Check torch consumables -
replace if necessary.
RECOMMENDED
COURSE OF ACTION
1. With 60 PSI applied to the
machine the air pressure
switch should be “closed.”
Check for continuity (less
than 1 ohm) between leads 
#319 to #323. See wiring
diagram.
2. Check the air solenoid 
(SV1) operation by apply-
ing 115 VAC to the solenoid 
leads.
a.  If the solenoid activates 
and air flows, the solenoid 
is good.  
b.  If the solenoid does not 
activate, replace the 
solenoid.
3. Check plug J10 on the 
Control Board for loose or 
faulty connections.
4. The Control Board could 
be faulty.  Replace.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln
Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.
AIR FLOW PROBLEMS
CAUTION