Electrolux 7.05 Compact ユーザーズマニュアル

ページ / 30
DOC. NO. 5956.677.00
P. 25 / 30
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
C1.3
PARAMETRI DI CONFIGURAZIONE
Inverter Telemecanique AH var 11 type ATV11PU12M2E380
Parameters for 110Vac gearmotor (Delta connection)
Parameter
Description
Standard machine
ACC
Acceleration ramp time
3.0
dEC
Deceleration ramp time
0.5
LSP
Low speed
0.0
HSP
High speed
100
ItH
Motor thermal current
3.6
SP2
2nd preset speed
10
SP3
3rd preset speed
25
SP4
4th preset speed
50
Alt
Act
Scale of analog input
10U
drC
UnS
Nominal motor voltage
110
FrS
Nominal motor frequency
50
StA
Frequency loop stability
20
FLG
Frequency loop gain
50
UFr
Ir compensation
50
nCr
Nominal motor current
3.6
CLI
Current limit
3.9
nSL
Nominal motor slip
5
SLP
Slip compensation
100
COS
Nominal motor cosine
0.65
FUn
tCC
ACt
Type of control
2C
tCt
Type of two wire control
Lel
rrS
Reverse
nO
Ps2
LIA
Preset speed lia
nO
LIB
Preset speed lib
nO
HSP
LIA
Config. input Lia
nO
LIB
Config. input Lib
nO
tLS
0.0
PI
PIF
nO
LOC
Overload threshold
90
tOL
Time delay for overl. func.
0
API
Histeresis freq. reached
0.3
LUL
Underload threshold
60
tUL
Time delay for underl. func.
10
rSF
Fault reset
nO
rP2
LI
Second ramp
nO
LC2
LI
2nd limit current
nO
nST
Freewheel stop
nO
StP
Controlled stop on loss of line
FST
brA
Deceleration ramp adaptation
YES
AdC
ACt
Automatic dc injection
YES
tdC
Injection time on stopping
0.5
SdC
Injection current
2.9
SfT
ACt
Frequency range
LF
Sfr
Switching frequency
4
FLr
Catch on the fly
nO
dO
ACt
Analogic output do
OCr
Atr
Automatic restart
nO
bFr
Motor frequency
50
SCS
Configuration backup
nO
FCS
Reminder of the configuration
nO