Bunn FPG-2 ユーザーズマニュアル

ページ / 79
10
TROUBLESHOOTING
 
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems 
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic 
Technical Service Department.
•  Inspection, testing, and repair of electrical equipment should be performed only by qualified service
personnel.
•  All electronic components have ac voltage and dc voltage potential on their terminals. Shorting of ter-
minals or the application of external voltages may result in board failure.
•  Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent.
If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection 
at a terminal or crimp.
•  Make certain that all electrical connections are tight and isolated.
WARNING
•  Exercise extreme caution when servicing electrical equipment.
•  Turn power OFF when servicing, except when electrical tests are specified.
•  Follow recommended service procedures.
•  Replace all protective shields or safety notices.
Problem
Grinder will not start.
Remedy
(A) Plug-in the grinder.
(B) Check the voltage at the wall 
outlet with a voltmeter. It must be 
120 volts ac for 120 volt models, 
100 volts for 100 volt models, and 
230 volts for 230 volt models.
(A) Momentarily press the Off/On/
Start switch to the “START” posi-
tion.
(B) Refer to Service - Off/On/Start 
switch for testing procedures.
Press the “Reset” button, located on 
rear of the grinder. Listen carefully 
for a “click”. This resets the motor 
protection circuit and indicates that 
an overload may have been encoun-
tered by the motor.  (An overload can 
occur when something other than 
coffee is inserted into the hopper for 
grinding). Refer to Service - Circuit 
Breaker for testing procedure.
Refer to Service - Timer for testing 
procedures.
Probable Cause
1. No power or incorrect voltage
2. Off/On/Start switch
3. Circuit Breaker (Not applicable on 
Model LPG with capacitor)
4. Timer
41545 122209