Smeg HB96CSS-3 ユーザーズマニュアル

ページ / 19
36
Instructions for the installer
8. GAS CONNECTION
Before installation, make sure that the local distribution conditions (nature and
pressure of the gas) and the state of regulation of the appliance are compatible.
To connect the hob to the gas supply a flexible connection B is required which will
enable connection to the gas inlet of the top A. Always place a gasket C between
the two connections (Fig.1) and tighten the components with a tightening torque of
at most 10 Nm.
Fig. 1 
Connection to the gas supply network can be made using a rigid copper hose or
flexible steel hose with a continuous wall and in compliance with the guidelines
established by the standard UNI-CIG 7129.
Once the operation is complete, check the hose fittings for leaks using a soapy
solution; never use a flame. The cooker hob is preset for natural gas G20 (2H) at
a pressure of 20 mbar.
For supplying it with other types of gas, see chapter “9. ADAPTATION TO
DIFFERENT TYPES OF GAS”.
The gas inlet connection is threaded ½” external gas (ISO 228-1).
Connection with rigid copper hose:
The connection to the gas supply
network must be carried out in such a
way that it does not cause stresses of
any type on the appliance. The
connection can be made using the
adapter unit with double cone, always
inserting the supplied gasket C  in
between. Tighten the components with a
tightening torque of at most 10 Nm.
Connection with flexible steel hose:
Use only continuous wall stainless steel
hoses that comply with standard UNI-
CIG 9891, making sure to always insert
the supplied gasket C  between the
connection  B  and the flexible hose E.
Tighten the components with a
tightening torque of at most 10 Nm.
Fig. 2