Instructions for the installer 
 
13 
4. FINAL 
OPERATIONS 
After replacing the nozzles, reposition the flame-spreader crowns, the 
burner caps and the grids. 
 
4.1  Adjustment of the hob burner minimum level for natural gas 
Light the burner and take it to the minimum  . 
Remove the gas tap knob and turn the 
adjustment screw inside of the tap shaft 
(depending on the model) until there is a regular 
minimum flame. Replace the knob and check 
burner flame stability: (rapidly turning the knob 
from maximum to minimum position, the flame 
should not go out). Repeat the operation on all 
the gas taps.
 
 
4.2  Adjustment of the hob burner minimum level for LPG 
(propane) 
To regulate the minimum for LPG (propane), completely tighten 
(clockwise) the screw inside or next to the gas tap pin (depending on the 
model). 
 
4.3 
Arrangement of the burners on the hob 
 
 
Burners
 
 
 Auxiliary 
 Semi rapid 
 Wok