Vulcan-Hart GTS12-2 ユーザーズマニュアル

ページ / 22
 
17
 - 
 
ELECTRICAL CONNECTIONS 
 
Electrical and grounding connections must comply with the 
applicable portions of the National Electrical Code and/or other local electrical 
codes. 
Disconnect the electrical power to the griddle and follow lockout / 
tagout procedures. 
Since the griddle top is not fused, you must connect to a fused circuit equipped with a 
suitable disconnecting means as required by local authorities. 
 
Electrical Connections 
1. Remove the small junction box cover plate on the back of the unit.  This exposes the 
    GTS clamshell griddle line leads. 
 
2. Select a suitable knockout on the sides or bottom of the junction box. 
 
3. Connect the griddle’s line leads to the supply wires with factory supplied wire connectors as shown 
    in the applicable wiring diagrams. 
     
 
4. Push the excess wire into the junction box and replace the cover plate. Never operate griddle 
    without cover in place. 
 
 
 
 
 
 
 
 
 
 
 
 
ELECTRICAL SPECIFICATIONS 
Model No 
Description 
Voltage 
Power 
1 Phase 
Draw 
GTS12‐1 
Front Grease 
Trough Models 
208 V 
3.6 kW 
17.3 A 
GTS12‐2 
240 V 
3.6 kW 
15 A 
GTS12‐3R 
Rear Grease 
Trough Models 
208 V 
3.6 kW 
17.3 A 
GTS12‐4R 
240 V 
3.6 kW 
15 A