Xerox GF761RFX ユーザーズマニュアル

ページ / 16
GB
5
Burner and nozzle specifications
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal
power
kW
(p.c.s.*
Thermal
power
kW
(p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal
power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
Ridot.
Nomin.
(mm)
(mm)
***
**
Nomin.
(mm)
Reduced Fast (RR)
100
0.70
2.60
39
80
189
186
2.60
110 (Y)
248
Semi Fast (S)
75
0.40
1.90
28
70
138
136
1.90
106
181
Auxiliary (A)
55
0.40
1.00
28
50
73
71
1.00
79
95
Triple Crown (TC)
130
1.50
3.30
61
91
240
236
3.60
145 (H1) 343
Semi-Fishburner (SP)
0.70
1.50
39
60
109
107
1.50
88
143
Double flame (DCDR internal)
30
0.40
0.90
28
44
65
64
0.90
74
86
Double flame (DCDR external)
2 nozzle
130
1.50
4.10
61
70
298
293
4.10
110
390
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
3
DC
S
A
SP
RR
TC
S
S
A
GF761RFX
GF750TX
The hob can only be installed above built-in ovens with a cooling ventilation system.