Dimensions and Installation Information 
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
Dimension and installation information are shown in inches.
Listed by 
Underwriters 
Laboratories
PP989SN 
GE Profile
™ 
30" Downdraft Electric Cooktop
 
Specification Created 7/08
220978
Installing the Ductwork: Use galvanized  
or aluminum duct in 6” round or 3-1/4” x  
10” size, or combination of both. 
PVC duct 
or locally approved piping should be used 
if installing under a poured concrete slab. 
Local building code must be followed in  
specifying type and schedule of all duct used.
Note: Ductwork must be vented to outside. 
Do not vent into a wall, ceiling, crawlspace, 
attic or any concealed space. Always use  
an appropriate roof or wall cap with damper. 
Laundry-type wall caps should never 
be used. For maximum efficiency use the 
shortest and straightest duct run possible, 
with as few fittings as possible.  
For satisfactory performance the duct run 
should not exceed 100 feet equivalent length.  
Refer to the table of equivalent lengths  
(shown in installation instructions) for  
various duct configurations.
Rear Wall Venting
Downward Venting
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof
Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8