INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools needed
Parts supplied
Vent grille
Grease filter
Grill cartridge
Grease container(s)
Hold-down straps (4) 
Clamping screws (4)
Parts needed
A UL listed or CSA approved strain relief for 
⁷⁄₈" (2.2 cm) 
knockout.
A UL listed or CSA approved conduit connector for 
¹⁄₂" (1.3 cm) trade-size metal-clad conduit
UL listed wire connectors
Metal ducting
Jenn-Air wall cap
Jenn-Air
® 
6" (15.2 cm) Round Surface Wall Cap Damper
Order Part Number A406
Jenn-Air
®
 3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper
Order Part Number A403
To order, see the “Assistance or Service” section of the Use 
and Care Guide.
Vent clamps
Check local codes. Check existing electrical supply. See 
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. 
When installing cooktop, use minimum dimensions given.
To eliminate the risk of burns or fire by reaching over the 
heated surface units, cabinet storage space located above 
the surface units should be avoided. If cabinet storage is to 
be provided, the risk can be reduced by installing a range 
hood that projects horizontally a minimum of 5" (12.7 cm) 
beyond the bottom of the cabinets.
Use the countertop opening dimensions that are given with 
these Installation Instructions. Given dimensions are 
minimum clearances and provide 0" (0 cm) clearance.
Grounded electrical supply is required. See “Electrical 
Requirements” section.
If cabinet has drawers, drawers will need to be removed and 
drawer fronts installed on front of cabinet.
IMPORTANT: An under-counter built-in oven cannot be installed 
under this product.
Product Dimensions
30" (76.2 cm) Cooktop
*A minimum clearance of 
6¹⁄₄" (15.9 cm) is recommended for 
removal of the grease containers. Installed dimension for the 
grease containers is 5
¹⁄₂" (14.0 cm).
**A minimum clearance of 
2" (5.1 cm) is recommended between 
the motor/blower and cabinet for proper cooling.
Tape measure
Flat-blade screwdriver
Phillips head screwdriver
Drill
Level
6" socket extension
Marker or pencil
Pliers
¼" drill bit
Jigsaw
Ratchet with 
³⁄₈" socket
A. Tie down bolt (on each side of cookop)
B. 30" (76.2 cm)
C. 21
³⁄₄" (55.3 cm)
D. Grease containers
E. Wiring box cover
F. Blower
A. 6
¹⁄₄" (15.9 cm)
B. 3
¹⁄₂" (8.9 cm)
C. Grease containers
D. 2" (5.1 cm)
E. 13
³⁄₄" (34.9 cm)
F. 11
¹³⁄₁₆" (30.0 cm)
G. 4" (10.2 cm)
H. 13
¹³⁄₁₆" (35.1 cm)
B
C
A
F
E
D
A*
B
D** 
E
F
G
H
C
C