Zephyr EBO-E36ASX ユーザーズマニュアル

ページ / 22
9
www.zephyronline.com
Inst
allation 
 - 
D
uctwork 
Calculation 
Sheet
3 1/4 ” x 10”
Rect.,
straight
6 ” Round,,
straight
7",  8”
Round,,
straight
3 1/4 ” x 10”
Rect.90°
elbow
3 1/4 ” x 10”
Rect.45°
elbow
3 1/4 ” x 10”
Rect.90°
flat  elbow
3 1/4 ” x 10”
Rect.
wall  cap
with  damper
3 1/4 ” x 10”
Rect.to
6 ” round
transition
3 1/4 ” x 10”
Rect.to
6 ” round
transition
90°  elbow
6 ” Round,,
90°  elbow
6 ” Round,,
45°elbow
1 Ft.
x  (
) =
1 Ft.
x  (
) =
1 Ft.
x  (
) =
15 Ft. x  (
) =
9 Ft.
x  (
) =
24 Ft. x  (
) =
30 Ft. x  (
) =
5 Ft.
x  (
) =
15 Ft. x  (
) =
15 Ft. x  (
) =
9 Ft.
x  (
) =
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
6" Round
wall  cap
with  damper
6” Round,
roof  cap
6” Round to
3 1/4 ” x 10”
rect.
transition
6” Round to
3 1/4 ” x 10”
rect.
transition
90°  elbow
7", 8" round
90°  elbow
7", 8" round
45°  elbow
7", 8" Round
wall  cap
with  damper
7", 8"
Round,
roof  cap
7” Round to
3 1/4 ” x 10”
rect.
transition
6” Round to
3 1/4 ” x 10”
rect.
transition
90°  elbow
30 Ft. x  (
) =
30 Ft. x  (
) =
1 Ft.
x  (
) =
16 Ft. x  (
) =
15 Ft. x  (
) =
9 Ft.
x  (
) =
30 Ft. x  (
) =
30 Ft. x  (
) =
8 Ft.
x  (
) =
15 Ft. x  (
) =
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Duct  pieces
Equivalent number
lenght x used =
Total
Duct  pieces
Equivalent number
lenght x used =
Total
Subtotal column 2 =
Subtotal column 2 =
Total  ductwork
=
Subtotal column 1 =
Maximum  Duct  Length:  For  satisfactory  air  movement,  the  total
duct length should not exceed 100 equivalent feet.