Lincoln 3270 ユーザーズマニュアル
Global
Lincoln
™
Warranty:
All 3200 series Impinger
®
ovens installed in the United States and Canada come with a two (2) year parts and
labor warranty starting from the date of start-up/check-out. All ovens installed in locations other than the US
and Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/
check-out. Start-up/check-out must occur within eighteen (18) months of date of manufacture.
and Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/
check-out. Start-up/check-out must occur within eighteen (18) months of date of manufacture.
General Information | 3255 Natural Gas Ovens:
General Information | 3270 Natural Gas Ovens:
General Information | 3255 Propane (LP) Gas Ovens:
General Information | 3270 Propane (LP) Gas Ovens:
Burner Capacity
BTU/hr (MAX)
Voltage
Hertz
Phase
Amps
Gas Supply Pressure
Inches, Water
Column
Gas Pipe
Size (NPT)
Single Oven
145,000
120
60
1
7
8”-14”
1”
Double Stack
290,000
120
60
1
14
8”-14”
1¼”
Triple Stack
435,000
120
60
1
21
8”-14”
1½”
Burner Capacity
BTU/hr (MAX)
Voltage
Hertz
Phase
Amps
Gas Supply Pressure
Inches, Water
Column
Gas Pipe
Size (NPT)
Single Oven
160,000
120
60
1
14
8”-14”
1”
Double Stack
320,000
120
60
1
28
8”-14”
1¼”
Triple Stack
480,000
120
60
1
42
8”-14”
1½”
Burner Capacity
BTU/hr (MAX)
Voltage
Hertz
Phase
Amps
Gas Supply Pressure
Inches, Water
Column
Gas Pipe
Size (NPT)
Single Oven
145,000
120
60
1
7
11.5”-14”
¾”
Double Stack
290,000
120
60
1
14
11.5”-14”
1”
Triple Stack
435,000
120
60
1
21
11.5”-14”
1¼”
Burner Capacity
BTU/hr (MAX)
Voltage
Hertz
Phase
Amps
Gas Supply Pressure
Inches, Water
Column
Gas Pipe
Size (NPT)
Single Oven
160,000
120
60
1
14
11.5”-14”
¾”
Double Stack
320,000
120
60
1
28
11.5”-14”
1”
Triple Stack
480,000
120
60
1
42
11.5”-14”
1¼”
Ventilation Requirements:
Ventilation is required. Local codes prevail. These are the “authority having jurisdiction” as stated by the
National Fire Protection Association, Inc. in NFPA 96-1994. Consult the Impinger® 3255/3270 Installation and
Operations Manual for ventilation recommendations.
National Fire Protection Association, Inc. in NFPA 96-1994. Consult the Impinger® 3255/3270 Installation and
Operations Manual for ventilation recommendations.