Installation (cont.)
Specifications:
PM45-B
PM4-B
OPERATING AND ADJUSTMENTS
Explanation of terms
All descriptions related to dispensing heads, dispensing buttons,
pump motors such as: push button #1, dispensing head #2, pump
motor #3 etc. are used in relation to the front of the machine. This
relates also to all components inside of the machine that are
symmetrically positioned. (See Figure C)
pump motors such as: push button #1, dispensing head #2, pump
motor #3 etc. are used in relation to the front of the machine. This
relates also to all components inside of the machine that are
symmetrically positioned. (See Figure C)
For example:
Push button #1 - Far left positioned dispensing push button.
Push button #4 - Far right positioned dispensing push button.
Dispensing head #3 - All components involved when dispensing
caused by depressed push button #3.
caused by depressed push button #3.
Pump motor #4 - Pump motor that works when push button #4 was depressed and is positioned inside the
machine in line with push
button.
machine in line with push
button.
Brix Setup
If initial concentrate brix is 60 and required mixing ratio is 6+1/6:1 (6 ounces water to one part concentrate),
then brix of ready to drink mixture of a concentrate and water should be 10.
then brix of ready to drink mixture of a concentrate and water should be 10.
To measure brix level, a refractometer is used to show sucrose content in a drink by measuring change of the light
diffraction in the water caused by change of viscosity due to sucrose content.
diffraction in the water caused by change of viscosity due to sucrose content.
The correct ratio is achieved by controlling water and a concentrate flow to the mixing device, in this case mixing
chamber. Brix on each dispensing head is preset in the factory. In the field, the brix needs to be fine-tuned to the
chamber. Brix on each dispensing head is preset in the factory. In the field, the brix needs to be fine-tuned to the
POWER SUPPLY:
220 VAC 50 Hz
115/60Hz
COMPRESSOR:
HP: 1/4, (630 Kcal, 2500 BTUH)
REFRIGERANT:
R134a 260 grams/9.1 oz.
DESIGN LOW PRESSURE:
Max. 9.5 BAR; 140 PSIG
DESIGN HIGH PRESSURE:
Max. 16.3 BAR; 240 PSIG
SYSTEM TYPE:
CAPILLARY TUBE, HERMETIC
IDLE POWER CONSUMPTION
.5A
.8A
RUN POWER CONSUMPTION
4A, 5A (MAX)
7A, 8A (MAX)
FUSE SIZE
6 A Slow Blow Controller
DISPENSING RATIO
50 ML/SEC
SUPPLY WATER PRESSURE
2 - 2.7 BAR; 29-40 PSIG
WORKING AMBIENT TEMPERATURE
15.5
°
C - 32.2
°
C 60-90ÞF(guaranteed performance)
PRODUCT STORAGE CAPACITY
NOM. 4 LITERS (FOUR 1L TETRAPACK)
(Figure C)