10   Release and Migration Notes - Bugfixes Included with Barracuda NG Firewall 5.0.3
Bugfixes Included with Barracuda NG Firewall 5.0.3
Barracuda NG Admin
Barracuda NG Installer
Barracuda NG Firewall
Table 1–6 
Barracuda NG Admin
Description
Within the 
Network Interface Configuration
, pop-ups erroneously appeared every time after changing the 
Appliance Sub Model 
Type
 in a VLAN interface. This issue was fixed.
In rare cases, the 
Send Changes 
button was erroneously disabled within the 
Personal Firewall Rules Configuration
. This issue 
was fixed.
Updating two units within two different tabs in Barracuda NG Admin at the same time resulted in failing update procedures. This 
issue was fixed.
Table 1–7 
Barracuda NG Installer
Description
Barracuda NG Installer was for virtual appliances in some cases erroneously not setting the model version as intended, leading to 
configuration problems in Barracuda NG Admin subsequent to the installation process. This issue was fixed.
Barracuda NG Installer failed to execute automated USB thumb drive installations on flash-based appliances if there were additional 
USB devices connected to the appliance. The following error message was generated:
An error occurred finding the installation image on your hard drive. Please check your images and 
try again.
This issue was fixed.
Table 1–8 
Barracuda NG Firewall
Module
Description
Authentication
Occasionally, a few log lines were missing in the authentication log. This issue was fixed.
Authentication
Occasionally, the firewall authentication daemon was erroneously blocking requests if these requests 
were sent delayed by the respective clients. This issue was fixed.
Authentication
Active Directory offline group synchronization was erroneously not using SSL even when it was 
configured to use it. This issue was fixed.
Barracuda OS
HDD performance I/O statistics were erroneously not logged. This issue was fixed
Barracuda OS
An issue within the VPN Client-to-Site and SSL VPN NAC licenses prevented these licenses from being 
correctly recognized on VF1000 (and probably also other Vxxxx) virtual appliances. This issue was fixed.
Barracuda OS
On VF250 virtual machines, it could erroneously happen that P2P detection generated an error stating 
that the license for P2P detection was limited to 100 units, although the license was not limited to this 
value. This issue was fixed.
Firewall
Big amounts of global firewall objects were, even if they were not referenced in a ruleset, leading to high 
memory consumption. This issue was fixed.