Mitsubishi Electronics SW3D5C-ACT-E ユーザーズマニュアル
6 - 52 6 - 52
MELSOFT
6 COMMUNICATION SETTING EXAMPLES OF THE UTILITY SETTING TYPE
6.8 CC-Link Communication
This section provides the CC-Link communication procedure and its setting example
using the utility setting type.
using the utility setting type.
6.8.1 Accessing procedure
The procedure for making access to the programmable controller CPU using CC-Link
communication will be explained in the following order.
communication will be explained in the following order.
START
Set the CC-Link board.
Connect the IBM-PC/AT compatible to CC-Link.
Start the communication setup utility and make
setting on the communication setting wizard.
setting on the communication setting wizard.
On the communication test screen, check whether
communication can be made properly.
communication can be made properly.
END
Refer to Chapter 2
and Section 6.8.1 (2).
and Section 6.8.1 (2).
Refer to Section 6.8.1 (3).
Refer to Section 6.8.1 (4).
(1) System
example
The following system example is used in this section.
CC-Link
Logical station number of "6" is used.
Local station
Station number 1
Number of occupied
stations 4
Station number 1
Number of occupied
stations 4
IBM-PC/AT compatible
(MX Component) First
CC-Link board is used.
(MX Component) First
CC-Link board is used.
Transmission speed: 10Mbps
Q02H
CPU
Local station
(Sta. No.5)
*
Accessible to the FXCPU with CC-Link communication only via the serial/USB
connection of the QCPU or via the Q series-compatible C24.
connection of the QCPU or via the Q series-compatible C24.
Supported CPUs and module in CC-Link communication to FXCPU are as follows.
CC-Link module
Compatible CPU
Station number
FX
3U
-64CCL FX
3G
,FX
3U(C)
1 to 63