OPERATING INSTRUCTIONS 
This section gives explanation of instructions in the following order. 
1)  Instructions for used OS and personal computer 
2)  Instructions for installation and uninstallation 
3)  Programmable controller CPU-related instructions 
4)  Instructions for the use of other MELSOFT products 
5)  Instructions for the use of Ethernet modules 
6)  Instructions for the use of CC-Link modules 
7)  Instructions for the use of MELSECNET(II), MELSECNET/10 and MELSECNET/H 
8)  Instructions for the use of computer link and serial communication modules 
9)  Instructions for modem communication 
10)  Instructions for programming 
11)  Instructions for the use of Microsoft
R
Excel 
12)  Instructions for the use of Microsoft
R
Access 
13)  Instructions for the use of VBScript and ASP function 
 
Instructions for used OS and personal computer  
(1) When using Microsoft
R
Windows NT
R
Workstation Operating System Version 4.0, 
Microsoft
R
Windows
R
2000 Professional Operating System,  
Windows
R
XP, Windows Vista
R
or Windows
R
Note that the following restrictions apply when a user without Administrator’s 
authority operates MX Component. 
(a)  Communication Setup Utility 
•  The logical station number cannot be created, changed or deleted. 
•  Target settings cannot be imported. 
•  This utility cannot be started up if the communication settings have been 
made using MX Component earlier than Version 3.00A. *1 
(b)  PLC Monitor Utility 
•  This utility cannot be started up if the communication settings have been 
made using MX Component earlier than Version 3.00A. *1 
•  Device registration cannot be performed on "Entry Device" tab. 
(c) Communication 
board 
•  Various settings cannot be made on the CC-Link IE Controller Network, 
MELSECNET/H, MELSECNET/10, MELSECNET(II), CC-Link, AF and 
CPU board utilities. 
*1:  If the following error message appears, start up and close the utility as a user 
with Administrator’s authority, once.  This operation enables a user without 
Administrator’s authority to start up the utility. 
 
 
(2)  About Ethernet communication, computer link communication and CPU COM 
communication on Microsoft
R
Windows
R
95 Operating System 
(a)  Making Ethernet communication using TCP/IP and UDP/IP on Windows
R
95 
of the version older than OSR2 will cause a memory leak. When performing 
continuous operation on Windows
R
95, use Windows
R
95 OSR2 or later.