Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.
Continuous product development may necessitate specification changes and design without notice. 
Victory R
Refrigeration, IInc.
Extra-H
High R
Roll-iin FFreezers 
Crated dim. & wts.
Ht. Width Depth Cu.Ft. Lbs
One Section
92
1
/
2
41
3
/
4
44
3
/
4
94.1 720
Two Section
92
1
/
2
74
5
/
8
44
3
/
4
168.1 1090
Three Section
92
1
/
2
107 44
3
/
4
241.1 1470
Approximate Roll-Thru weights, add 15%
FOR REMOTE MODELS– Substitute an “R” for the “S” in suffix. For
example: Model FIS-1D-S7 (self-contained) would be FIS-1D-R7
remote cabinet. Air circulating fans, expansion valve and plasticized
coil are provided. Condensing units not supplied. The following units
are recommended with 
1
/
2
” O.D. Suction line, 
1
/
4
” O.D. Liquid line.
Dimensional tolerance ± 
1
/
4
”   Metric dimensions (MM)
REMOTE REFRIGERATION
Cond. Unit
BTUH
Cabinet
Amps*
One Section
3
/
4
H.P.
2540
115/60/1
4.9
Two Section
1 H.P.
4400
115/60/1
7.8
Three Section 2.5 H.P.
5800
115/60/1
8.5
*(In Defrost)
For Remote Roll-Thru–Consult factory
Copyright November 2007
Printed in U.S.A.
PART OF AGA FOODSERVICE GROUP
39.38
(1000)
35.88
(911)
31.25
(793)
.88
(22)
72.25
(1835)
27.75
(705)
89.50
(2273)
36.50
(927)
ELEC.
CONN.
ELEC.
CONN.
72.25
(1835)
.88
(22)
27.75
(705)
27.75
(705)
89.50
(2273)
68.88
(1749)
39.38
(1000)
35.88
(911)
63.62
(1616)
ELEC. CONN.
ELEC. CONN.
89.50
(2273)
101.25
(2571)
72.25
(1835)
.88
(22)
27.75
(705)
27.75
(705)
27.75
(705)
96.00
(2438)
ELEC. CONN.
ELEC. CONN.
39.38
(1000)
35.88
(911)
ROLL-IN MODELS
ROLL-THRU MODELS
35.50 (902)
  TO RAMP
34.88
(873)
14.12
(358)
32.38
(822)
NOTE:  If cabinet is located directly against
wall and/or under low ceiling, a minimum
clearance of 2” is required.
We reserve the right to change specifications
and product design without notice. Such
revisions do not entitle the buyer to
corresponding changes, improvements,
additions or replacements for previously
purchased equipment.
CHARACTERISTICS
ONE SECTION 
TWO SECTION
THREE SECTION
Roll-In
Roll-Thru
Roll-In
Roll-Thru
Roll-In
Roll-Thru
Width, Overall
36 
1
/
2
36 
1
/
2
68 
7
/
8
68 
7
/
8
101 
1
/
4
101 
1
/
4
Depth, Overall (incl. handles)
35 
7
/
8
39 
3
/
8
35 
7
/
8
39 
3
/
8
35 
7
/
8
39 
3
/
8
Height, Overall 
89 
1
/
2
89 
1
/
2
89 
1
/
2
89 
1
/
2
89 
1
/
2
89 
1
/
2
Depth, Door(s) Open 90º
65 
1
/
4
65 
1
/
4
65 
1
/
4
65 
1
/
4
65 
1
/
4
65 
1
/
4
Depth Cast Over Ramp
35
1
/
2
35
1
/
2
35
1
/
2
35
1
/
2
35
1
/
2
35
1
/
2
Clear Door Width
27 
3
/
4
27 
3
/
4
27 
3
/
4
27 
3
/
4
27 
3
/
4
27 
3
/
4
Clear Full Door Height
72 
1
/
4
72 
1
/
4
72 
1
/
4
72 
1
/
4
72 
1
/
4
72 
1
/
4
Capacity Net (cubic feet)
36.3
36.3
72.6
72.6
108.9
108.9
No. of Full Doors
1
2
2
4
3
6
Cabinet Voltage
115/60/1
115/60/1 115/60/1
115/60/1 115/60/1 115/60/1
Feed Wires
3
3
32
3
3
3
Condensing Unit Voltage
208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-30/60/1
Condensing Unit Size (HP)
3
/
4
1
1
2
2.5
2.5
Total Amperes
10.9
13.1
13.9
18.2
22.7
22.7