Liebherr 7081998-0 ユーザーズマニュアル

ページ / 10
3 Controls and displays
3.1 Operating and control elements
Fig. 3 
(1) On/Off button
(6) Menu symbol
(2) Setting button
(7) Alarm symbol
(3) Temperature display
(8) Brightness symbol
(4) SuperFrost button
(9) Child lock symbol
(5) SuperFrost symbol
3.2 Temperature display
The following are displayed in normal operation:
-
the set freezing temperature
The temperature display flashes:
-
the temperature setting is being changed
-
after switch-on the temperature is not yet cold enough
-
the temperature has risen several degrees
4 Putting into operation
4.1 Transporting the appliance
CAUTION
Risk  of  injury  and  danger  of  damage  as  a  result  of  incorrect
transport!
u
Transport the appliance in a packed condition.
u
Transport the appliance upright.
u
Do not transport the appliance without assistance.
4.2 Installing the appliance
WARNING
Fire hazard due to dampness!
If  live  parts  or  the  mains  lead  become  damp  this  may  cause
short circuits.
u
The appliance is designed for use in enclosed areas. Do not
operate  the  appliance  outdoors  or  in  areas  where  it  is
exposed to splash water or damp conditions.
WARNING
Risk of fire due to short circuit!
If  the  mains  cable/connector  of  the  appliance  or  of  another
appliance  touch  the  rear  of  the  appliance,  the  mains  cable/
connector  may  be  damaged  by  the  appliance  vibrations,
leading to a short circuit.
u
Stand the appliance so that it is not touched by connectors
or main cables.
u
Do not plug the appliance or any others into sockets located
near the rear of the appliance.
WARNING
Fire hazard due to refrigerant!
The  refrigerant  R  600a  is  environmentally  friendly  but  flam-
mable. Escaping refrigerant may ignite.
u
Do not damage the piping of the refrigeration circuit.
WARNING
Fire hazard and danger of damage!
u
Do  not  place  appliances  emitting  heat  e.g.  microwaves,
toasters etc. on the appliance!
WARNING
Blocked ventilation openings pose a risk of fire and damage!
u
Always keep the ventilation openings clear. Always ensure
that the appliance is properly ventilated!
q
In  the  event  that  the  appliance  is  damaged,  contact  the
supplier immediately before connecting to the mains.
q
The floor at the site must be flat and level.
q
Do not install the appliance in a location where it is exposed
to  direct  radiation  of  the  sun,  next  to  a  cooker,  heater  and
similar.
q
The ideal installation site is a dry, well ventilated room.
q
Always stand the appliance with its back directly to the wall.
q
The appliance may be moved only when it is empty.*
q
Do not install the appliance without assistance.
q
Standard EN 378 specifies that the room in which you install
your  appliance  must  have  a  volume  of  1  m
2
  per  8  g  of  R
600a refrigerant used in the appliance. If the room in which
the  appliance  is  installed  is  too  small,  a  flammable  gas-air
mixture may form in the event of a leakage in the refrigera-
tion circuit. The quantity of refrigerant used in your appliance
is indicated on the type plate on the inside of the appliance.
u
Detach the connecting cable from the rear of the appliance,
removing the cable holder at the same time because other-
wise there will be vibratory noise!
u
Remove all transit supports.
u
Dispose of packaging material (see 4.5) .
u
Align  the  appliance  so  that  it
stands firmly and on a level by
applying  the  accompanying
spanner  to  the  adjustable-
height  feet  (A)  and  using  a
spirit level.
Note
u
If  the  appliance  is  installed  in  a  very  damp  environment,
condensate may form on the outside of the appliance.
u
Always see to good ventilation at the installation site.
4.3 Changing over the door hinge*
You can change over the door hinges if necessary.
Make sure that the following tools are at hand:
q
Supplied open-ended wrench
Controls and displays
4